Télécharger Imprimer la page

Miele PW 6321 EL Mode D'emploi page 16

Publicité

Les langues disponibles

Les langues disponibles

en - Technical details
Hot water connection EH
Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose supplied
Hard water connection
Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose supplied
Waste water (drain valve)
Maximum waste water temperature
Machine-side drain connection (external diameter)
On-site drain (internal diameter)
Maximum flow rate
A vented combined pipe is required to drain the waste water. If several machines are connected to a single drain pipe, this should be
sufficiently large to allow all machines to drain simultaneously.
Securing the machine
Fasteners
4 x wood screws DIN 571 (Ø x length)
4 x plugs (Ø x length)
Fixing the machine in place is absolutely essential.
Emissions
Average heat dissipation rate to installation site
A-weighted noise power level in accordance with EN ISO 9614, part 2
16
194°F (90°C)
14.5-145 psi (1–10 bar)
4.5 gpm (16 l/min)
1 x 61" (1550 mm)
14.5-145 psi (1–10 bar)
8.5 gpm (32 l/min)
2 x 61" (1550 mm)
203°F (95°C)
HT DN 70 (2 15/16")
2 15/16" x 13/16" x 4 5/16" (75 x 1.9 x
110 mm sleeve DN 70)
52.8 gpm (200 l/min)
12 mm x 90 mm
16 mm x 80 mm
73 dB(A) re 20 µPa
1"
3/4"
6.1 MJ/h

Publicité

loading

Ce manuel est également adapté pour:

Pw 6321 ehPw 6321 el mf