The drip tray should be cleaned once a month or

Drip tray

as needed.
To remove the drip tray, first remove the baffle
grease filters. Grasp both ends of the drip tray.
Gently lift the drip tray up until the bottom of it
clears the track. Pull the drip tray forward, being
careful not to spill the contents, and move it to a
nearby trash receptacle.
To clean the drip tray, drain and wipe all excess
grease with a dry paper towel. Wash with warm
soapy water or in the dishwasher. Dry with a
clean cloth.
To replace the drip tray, lift it up and into the
track on the hood. Replace baffle grease filters.
nOte: The glass cover should be removed only when cool.

Light bulbs

Before replacing the bulb, disconnect electrical
power to the hood at the main fuse or circuit
breaker or main power disconnect switch located
on the control housing. Allow bulbs to cool before
touching.
For safety, do not touch a hot bulb with bare hands
or a damp cloth.
to change the light bulbs:
1. Remove the lamp lens cover by inserting a small
flat-blade screwdriver into each of the three slots
and gently prying it free.
nOte: Do not remove the outer trim ring (lamp
assembly).
2. Grasp the bulb and pull it straight out.
3. Using gloves or a dry cloth, remove the new bulb
from the packaging. (Wearing latex gloves may offer
a better grip.) The bulb must be the same wattage,
120-volt, 25-watt halogen with a G-9 base. Early-life
bulb failure may occur if wattage is too high.
4. Push the bulb straight all the way into the
receptacle.
5. Replace the lens cover by inserting the three
retaining tabs into the slots and pressing into place.
nOte: For improved lighting, clean the glass cover
frequently using a damp cloth. This should be done
when the hood is completely cool.
6. Reconnect electrical power to the hood.
nOte: Order replacement 120-volt, 25-watt
halogen bulb with G-9 base, WB25x10020.
These bulbs can be ordered from GE parts. Please see
Consumer Services page in the back of this manual.
CautIOn:
Care and Cleaning
Stainless Steel Hood
Drip tray
Use a small flat-blade screwdriver
to remove the lamp lens cover.
Tab
nOte: Make sure the tabs are
inserted into the slots.
OnLy use a new 120-volt, 25-watt
halogen bulb with a G-9 base.
Receptacle
Use gloves
or cloth
nOte: Do not touch the new halogen bulb
with bare fingers. Skin oils can cause early-
life bulb failure.
Bulb
Outer trim ring
(lamp assembly)
Do not remove
Removable inner
lamp lens cover