Key
Key press
L
Short
Long press with
light or motor on
Long press with
all loads off (mo-
tor and lights)
T1
Short
Long press with
light on
Long press with
all loads off (mo-
tor and lights)
T2
Short
Long press with
light or motor on
Long press with
all loads off (mo-
tor and lights)
T3
Short
Long press with
light or motor on
Long press with
all loads off (mo-
tor and lights)
12
Function
The lights alternate between high intensity, medium intensity (if
present), off.
Delay Function
Activates/Deactivates the Delay function (automatic shutdown of the
Motor and of the lighting delayed by 30').
Cannot be activated with Intensive or 24h function.
Connected mode coupling
Before starting the procedure follow the specific instructions of the
manuals of the devices to be coupled.
The procedure for pairing of the hood with compatible devices (re-
mote control) starts. Only one remote control can be paired. See the
manual of the devices for details of the operations that need to be
performed on these.
The coupling procedure takes 2 minutes. If no devices are recognised
within this time check that you have previously activated the proced-
ure for the devices to be coupled. The maximum number of linkable
devices may have been reached.
Turns the motor on/off at the first speed.
Activates/Deactivates the Activated Carbon Filters alarm.
Connected mode decoupling
The procedure for deleting all compatible devices previously associ-
ated with the coupling function begins.
Turns the motor on/off at the second speed.
24h Function
Activates/Deactivates the motor in the 24h Air Exchange mode, a
speed that allows suction of 10 minutes every hour, for a 24-hour
cycle.
Cannot be activated if the Intensive or Delay modes are active.
Wi-Fi connection
Activates/Deactivates the Wi-Fi Connection function.
Note: the Wi-Fi function is automatically activated when the user re-
quests the Wi-Fi configuration procedure.
Turns the motor on at the third speed.
Turns the motor on at the Intensive 1 speed.
This speed is timed for 10 minutes. At the end of this time, the system
automatically returns to the previously selected speed. If activated
with the motor off, once the time has passed it switches to OFF mode.
By pressing the key again with a long press (with light or motor on),
the motor starts at the Intensive 2 speed.
This speed is timed for 6 minutes. At the end of this time, the system
automatically returns to the previously selected speed. If activated
with the motor off, once the time has passed it switches to OFF mode.
The Filter saturation alarm is reset.
Signals the saturated Metal Grease Filters alarm and the need to
wash them. The alarm is activated after 100 hours of effective hood
operation.
Signals the Activated Charcoal Odour Filter saturation alarm. The
alarm is activated after 200 hours of effective hood operation.
LED
-
Flashing
LEDs T1 and T2 flash-
ing:
coupling in progress.
Upon successful com-
pletion of the procedure
LEDs T1 and T2 will
light up for 2 seconds.
Fixed
All LEDs flash twice:
alarm activated.
All LEDs lit for 1
second:
alarm deactivated.
Upon successful com-
pletion of the procedure
LEDs T1 and T2 flash 5
times.
Fixed
Flashing
LED S1 Flashing:
connection to domestic
network in progress.
LED S1 Fixed: Wi-Fi
connection activated.
Fixed
Flashing
All LEDs flash 3 times.
LEDs T2 and T3 lit with
the hood off.
LEDs T2 and T3 flash-
ing with the hood off.