Other Components continued:
At this point you can access the primary air control
damper assembly, thermostatic actuator assembly
and the damper release lever. Although these
shouldn't need to be replaced, they can be, easily.
The primary air control damper assembly can be
replaced by removing the small spring handle from
the front of the unit, then sliding the assembly out.
Replace by sliding the new assembly through the
same hole and the rod through the front of the
stove. Replace the spring handle. The thermostatic actuator assembly can be replaced by using
a 5/16" socket to remove the two screws that hold the assembly. Install the new assembly using
the same two screws. The damper release lever can be replaced by removing the ½" bolt.
When reinstalling the damper be sure it is installed the same as when removed.
Blower: The wood stove was also designed for use with a convection blower for additional heat
circulation. The stove is constructed with side convection channels which allow the room air blower to
pick up heat from the hottest regions of the stove and transfer it into the home. The mounting screws
for the blower are installed into the rear convection channel at the factory; mounting the blower only
requires a 5/16" open end or socket wrench to remove these screws and install the blower. When
routing the power cord, take care to keep away from hot areas of the unit and remember that this
blower is for use only with the stove. Please see the diagram below for clarification on the room air
blower installation. This unit can use the AC‐16 (which comes standard with the unit) or the AC‐30
upgrade blower. Both are installed using the four factory installed 5/16" screws.
The optional heat circulation blower on this stove requires periodic lubrication; this lubrication should be performed
no less than every three months of normal operation. To properly lubricate the blower, use an eye dropper or
similar dispensing device to drip 5‐7 droplets of SAE 20 oil into the oil port on the side of the blower motor.
Side Heat Shield (Part AC‐W01SHS):
Install the side heat shield behind the side flange of the rear panel.
Align the two mounting holes and secure with the two screws
provided.
OPTIONAL ACCESSORIES
(4) 5/16" head, self‐tapping
screws (pre‐installed in unit).
Warning: Disconnect power
from fan before installation.
Page | 25