All manuals and user guides at all-guides.com
PROBLEM
Pressure reading on
It is normal for "some"
the regulated pressure
pressure drop to occur.
gauge drops when an
accessory is used.
Compressor is not
Prolonged excessive
supplying enough air to
use of air.
operate accessories.
Compressor is not
large enough for
air requirement.
Hole in hose.
Check valve restricted.
Air leaks.
Regulator knob has
Damaged regulator.
continuous air leak.
Regulator will not
Damaged regulator.
shut off air outlet.
CAUSE
CORRECTION
If there is an excessive
amount of pressure drop
when the accessory
is used, adjust the
regulator following
the instructions in
the Description of
Operation paragraph in
the Operation Section.
NOTE: Adjust the
regulated pressure
under flow conditions
(while accessory
is being used).
Decrease amount
of air usage.
Check the accessory
air requirement. If
it is higher than the
SCFM or pressure
supplied by your air
compressor, you need
a larger compressor.
Check and replace
if required.
Contact a Trained
Service Technician
Tighten fittings.
Replace.
Replace.
17 - ENG