Battery; Charging Procedure; Battery Handling; Environmental Protection - Gesipa FireBird Mode D'emploi

Masquer les pouces Voir aussi pour FireBird:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15

3.2.2. Battery

Caution:
Following safety rules must be follow-
ed for adequate protection against electrical
shock, injuries or fire hazards:
Never try to charge a damaged battery.
Do not insert a dirty or wet battery into the
charger.
Never throw batteries into the waste, into fire
or into water.
Do not charge a battery when the environment
temperature is below 0°C.

3.3. Charging procedure

Charge only GESIPA batteries when the environ-
ment temperature is between 0°C and 40°C.
Take the charger out of its package and
connect to mains. Check the input voltage on
the type label before connecting.
Insert the battery in the right way (pole+ to
pole+) into the charger bay. Insertion should
take place without noticeable effort.
The charging operation starts automatically
when the battery is inserted into the charging
bay.
Function lights:
Steady green: Battery is charged,
preserv.charge in process
Blinking green: Charging
Steady red:
Charging temperature out of range
(battery too hot or too cold)
Blinking red:
Battery is defective
Typical charging cycles:
Type
Part Number
1,4 Ah NiCd
725 1017
1,7 Ah NiCd
725 1092
2,0 Ah NiCd
725 1095
3,2 Ah NiMH
725 1030
*charging cycles may vary according to the rest capacity and the
battery temperature.
Charging cycle*
approx. 35 min
approx. 40 min
approx. 45 min
approx. 70 min

3.4. Battery handling

Use only cold batteries to obtain optimum
charging.
The GESIPA batteries can be charged approx.
1.000 times and reaches its maximum capacity
only after several charging cycles.
Do not insert the battery into the charger after
each use, but wait until the battery is fully dis-
charged (tool cannot set the rivet).
Recharge the battery after a long period of
inactivity.
Battery autonomy becoming shorter despite of
proper recharging means that the battery must
be replaced.
Keep the battery in dry and warm rooms.
The optimum operating temperature range is
10°C to 50°C.

3.5. Environmental protection

If batteries have to be replaced,
the following instructionsshould be
followed:
Bring back discarded batteries to your GESIPA
agent or to GESIPA for recycling.
Never throw away discarded batteries into
waste, fire or water.
13

Publicité

Table des Matières
loading

Table des Matières