2. Charger and battery
2.1. Technical characteristics
2.1.1. Battery charger
Type:
Input voltage:
Output voltage:
Output current:
Weight:
2.1.2. Battery
Nominal voltage:
Number of cells:
Cell:
Capacity:
Weight:
2.2. . Safety Instructions
2.2.1. Battery charger
Caution:
Following safety rules must be followed for ade-
quate protection against electrical shock, injuries
or fire hazards:
•
The charger must be exclusively used to charge
GESIPA batteries.
•
Check regularly cord, plug and device and have
it fixed by skilled personal when damaged.
•
Use exclusively genuine plugs and cords and
genuine spare parts for repair.
•
Never use the charger in humid or wet environ-
ment, or close to inflammable substances or
gases: Explosion hazard!
•
Take the charger out of its package before use.
Insert the battery in the right way (pole+ to
pole+) into the charger bay. Insertion should
take place without noticeable effort.
•
Never try to charge non rechargeable batteries.
•
Store the charger in a dry closed room, out of
reach of children.
•
Never insert metallic parts into the charging
bay: Short circuit hazard.
•
When the charger is wall-mounted, make sure
that the inserted battery cannot fall down.
•
Do not operate this battery charger at altitudes
exceeding 2.000 meter above sea level.
12
12355/12356
220-240VAC/50-60Hz
14,4VDC
1,5A max.
0,6kg
14,4VDC
4/8
Li-Ion
1,3Ah/2,6Ah
0,35/0,5kg
•
This battery charger should not be operated
neither by physically disabled or mentally
affected people, nor by untrained or unskilled
people.
2.2.2. Battery
Caution:
Following safety rules must be followed for ade-
quate protection against electrical shock, injuries
or fire hazards:
•
Never try to charge a damaged battery.
•
Do not insert a dirty or wet battery into the
charger.
•
Never throw batteries into the waste, into fire
or into water.
•
Do not charge a battery when the environment
temperature is below 0°C.
2.3. Charging procedure
•
Charge only GESIPA batteries when the environ-
ment temperature is between 0°C and 40°C.
•
Take the charger out of its package and connect
to mains. Check the input voltage on the type
label before connecting.
•
Insert the battery in the right way (pole+ to
pole+) into the charger bay. Insertion should
take place without noticeable effort.
•
The charging operation starts automatically
when the battery is inserted into the charging
bay.
Function lights:
Steady green: Battery is charged,
preserv.charge in process
Blinking green: Charging
Steady red:
Charging temperature out of range
(battery too hot or too cold)
Blinking red:
Battery is defective
Typical charging cycles:
Type
Part Number
1,3 Ah
725 1045
2,6 Ah
725 1049
*charging cycles may vary according to the rest capacity and the
battery temperature.
Charging cycle*
approx. 50 min
approx. 100 min