FILTER REMOVAL & INSTALLATION
WARNING: Do not operate
without filter cage and float, as they
prevent liquid from entering the
impeller and damaging the motor.
For dry material pick-up, do not
operate without the filter in place in
order to reduce the risk of damage
to the motor.
Filter Removal:
1. Hold the filter tabs of the Qwik Lock™
filter in each hand.
2. With one thumb on the Qwik Lock™
stud, which protrudes through the
integrated filter plate, lift up on the filter
tabs while pushing down on the stud.
3. This action will cause the filter to
release from the filter cage. Slide filter
off cage.
Filter Installation:
1. Carefully slide the Qwik Lock™ filter
over the filter cage and press down on
the outside edge of the filter until the
rubber gasket on the bottom of the filter
seats securely around the base of the
filter cage and against the lid.
2. Align the small center hole in the top of
the filter over the Qwik Lock™ stud on
the filter cage. Press firmly on top of
the filter near the stud to allow the filter
to snap over the ball on the end of the
stud. The filter is now attached.
NOTE: Failure to properly seat the bottom
gasket could result in debris bypassing
the filter.
Integrated Filter