Electrical Connections
6 Electrical Connections
6.1 Connect unit plug
6.1.1
Closed function
Connect the position indicator with the unit plug, wiring diagrams see
chapter 7.2
Connect
1
2
3
6.1.2
Opened function
Change connection No 4 on the microswitch, wiring diagrams see chapter 7.2
Connect No 2.
6.1.3
Change-over function
Remove the unit plug and the internal wiring
Install a PG11 cable gland.
Connect multiple wires directly to the microswitch connector lug.
Plat pin microswitches
1
2
4
32
Function
Normally open contact for «OPEN» position
Normally open contact for «CLOSED» position
Power supply for both microswitches
Function
Power supply
Normally closed
Normally open