PERFORMANCE DATA
Important Notice: Read performance data and compare
the capabilities of the system with your actual water
treatment requirements. It is recommended that the
supply water be tested, before installing a water treatment
system, to determine your water treatment needs.
Test Conditions
Flow Rate
-GRO-575B/GRO-575M
=0.60 gpm (2.27 L/min)
Inlet Pressure:
=60 psi (4.1 bar)
Temperature Range:
=68°F± 5°F (20°C+/- 2.5°F)
pH:
=7.5 ± 0.5
Filter Capacity
-GRO-575B/GRO-575M
= 675 gallons (2555 L)
Operating Requirements for GRO-575B
and GRO-575M Systems
Pressure
= 40-100 psi (2.75–6.89 bar)
Temperature
= 40-100°F (4.4–37.8°C)
This system has been tested according to NSF/ANSI 58 for
the reduction of substances listed below. The concentration
of the indicated substances in water enteringthe sysem
was reduced to a concentration less than or equal to the
permissible limit for water leaving the system as specified in
NSF/ANSI 58.
The GRO-575B/GRO-575M shall only be used for arsenic
reduction on chlorinated water supplies containing detectable
residual free chlorine at the system inlet. Water systems
using an in-line chlorinator should provide a one-minute
chlorine contact time before the RO system.
Do not use with water that is microbiologically
WARNING:
unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may contain
filterable cysts.
NOTE: Substances reduced are not necessarily in your water.
Filter must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
The tested efficiency rating for these systems is 23.57%.
Efficiency rating means the percentage of the influent water
to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate
typical daily usage.
The tested recovery rating is 41.05%. Recovery rating means
the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage
tank or when the storage tank is bypassed.
The GRO-575B/GRO-575M has been tested for the treatment
of water containing pentavalent arsenic [also known as As(V),
As(+5), or arsenate] at concentrations of 0.050 mg/L or less.
This system reduces pentavalent arsenic, but may not remove
other forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine residual or on
water supplies that have been demonstrated to contain only
pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufficient to ensure complete conversion
of trivalent arsenic to pentavalent arsenic. Please see the
Arsenic Facts section of the Performance Data Sheet for
further information.
System Production Rate:
Recovery Rating:
Efficiency Rating:
TDS Rejection:
Flow Rate:
EPA Est. No. 082989-CHN-001
GRO-575B/GRO-575M SYSTEM INSTALLED WITH FDF1-RC, GRO75-RC,
F2B2-RC2 CARTRIDGE SET and F1GC-RC CARTRIDGE
Substance
21.08 gpd (79.77 Lpd)
41.05%
23.57%
96.3%
0.6 gpm
FRESHPOINT GRO-575B/GRO-575M Installation and Operation Manual • 17
Average
Influent Challenge
Influent
Concentration
Concentration
Standard 42 - Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
2.1 mg/L
Taste & Odor
Standard 53 - Health Effects
Minimum 50,000
80,000
Cyst**
oocyst/L
oocyst/L
.0084 mg/L 0.003 mg/L / 0.002
Atrazine
0.009 mg/L ± 10%
Lead pH 8.5
0.15 mg/L ± 10%
0.150 mg/L
Lead pH 6.5
0.15 mg/L ± 10%
0.140 mg/L
Lindane
0.002 mg/L ± 10%
0.002 mg/L
Chloroform
(VOC surrogate
0.300 mg/L ± 10%
0.290 mg/L
chemical)
Perfluorooctanoic
acid (PFOA) and
0. 0015 mg/L ± 10%
perfluorooctane
sulfonate (PFOS))
Standard 58 - Reverse Osmosis
Total Dissolved
750 mg/L ± 40 mg/L
740 mg/L
Solids
Pentavalent
0.050 mg/L ± 10%
0.053 mg/L
Arsenic
Fluoride
8.0 mg/L ± 10%
8.4 mg/L
Minimum 50
Cyst**
120 particles/L 99.9% / <1/100L
particles/L
Turbidity
11 NTU ± 1 NTU
12 NTU
Lead
0.15 mg/L ± 10%
0.16 mg/L
Selenium
0.10 mg/L ± 10%
0.097 mg/L
Copper
3.0 mg/L ± 10%
2.9 mg/L
0.029 mg/L 0.005 mg/L / 0.004
Cadmium
0.03 mg/L ± 10%
Hexavalent
0.3 mg/L ± 10%
0.300 mg/L
Chromium
Trivalent
0.3 mg/L ± 10%
0.330 mg/L
Chromium
Radium 226/228
25 pCi/L ± 10%
-
Barium
10.0 mg/L ± 10%
9.7 mg/L
Test conditions: Flow Rate = 0.60 gpm; Inlet Pressure = 60 psi; Temperature = 68°F± 5°F; pH = 7.5 ± 0.5
*
USEPA Maximum Contaminant Level/Drinking Water Standards for New Zealand - Maximum Acceptable Values.
**
NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means.
These appliances meet the domestic water treatment appliance Standards AS/NZS
3497 and AS/NZS 4348 for the following water process:
Class
Treatment Type
Microbiological Status
I
Will stop bacteria increasing, but will not remove them unless II(a) is passed
Bacteriostatic
II
Microbiological Treatment
Bacteria removal
II(a)
Virus removal
II(b)
Will remove or inactivate Cryptosporidium and Giardia. Will not remove
Protozoa removal
II(c)
Turbidity and
III
particulate reduction
IV
Taste and Odour reduction
Chemical treatment
V
System Tested and Certified by NSF International
against NSF/ANSI Standard 42, 53, 58, and
CSA B483.1 for the reduction of the claims
specified on the Performance Data Sheet.
C
US
The models GRO-575B and GRO-575M are certified by IAPMO
R&T against NSF/ANSI 53 for the reduction of perfluorooctanoic
acid (PFOA) and perfluorooctane sulfonate (PFOS).
Maximum
Max. Permissible
Acceptable
Water
Reduction
Value
Concentration
Requirements
4 mg/L / 5 mg/L
-
≥ 50%
99.9% / <1/100L
-
99.95%
0.003 mg/L
-
mg/L
0.015 mg/L / 0.01
0.010 mg/L
-
mg/L
0.015 mg/L / 0.01
0.010 mg/L
-
mg/L
0.0002mg/L /
0.0002 mg/L
-
0.002 mg/L
Surrogate - See
0.015 mg/L
-
Table
0. 00007 mg/L
-
-
75%
0.010 mg/L / 0.010
0.010 mg/L
-
mg/L
4.0 mg/L / 1.5 mg/L
1.5 mg/L
-
-
99.95%
1 NTU / -
0.5 NTU
-
0.015 mg/L / 0.01
0.010 mg/L
-
mg/L
0.05 mg/L / 0.01
0.05 mg/L
-
mg/L
1.3 mg/L / 2.0 mg/L
1.3 mg/L
-
0.005 mg/L
-
mg/L
0.1 mg/L / 0.05
0.1 mg/L
-
mg/L
0.1 mg/L / 0.05
0.1 mg/L
-
mg/L
5 pCi/L / -
5 pCi/L
-
2.0 mg/L / 0.7
2.0 mg/L
-
mg/L
Function
Will remove or inactivate bacteria
Will remove or inactivate virus
or inactivate bacteria and virus unless II(a) and II(b) is passed
Reduces cloudiness
Reduces tastes and odours
Decreases certain chemicals
Reduces:
Chlorine - Atrazine - Lindane - VOC - Pentavalent Arsenic - Fluoride
Lead - Selenium - Copper - Cadmium - Hexavalent Chromium
Trivalent Chromium - Radium 226/228 - Barium
Legend: ✔= Pass,
Average
Effluent
Average
Concentration
Reduction
0.09 mg/L
95.9%
5 oocyst/L
99.99%
0.001 mg/L
93.7%
0.001 mg/L
99.6%
<0.001 mg/L
99.9%
0.00005 mg/L
97.4%
.002 mg/L
99.4%
98.06%
28 mg/L
96.3%
0.006 mg/L
88.0%
0.5 mg/L
93.6%
0.005
>99.99%
particles/L
<0.1 NTU
>99.1%
0.002 mg/L
98.6%
0.001 mg/L
97.9%
0.043 mg/L
98.5%
0.0003 mg/L
99.1%
0.011 mg/L
96.4%
0.006 mg/L
98.2%
-
80.0%
0.36 mg/L
96.3%
Pass
N/A
N/A
N/A
N/A = Not Applicable