User Guide Fleck 5810-XTR
3 .
Description
3.1.
Technical specifications
Pressure............................................ .............. Hydrostatic: 20 bar; Working: 1.4 - 8.6 bar
Maximum service flow rate (ΔP 1.7 bar): ........ 10.7 m
3.2.
Environmental conditions
• Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
• Main supply voltage fluctuations up to ±10% of the nominal voltage.
• Temperature from 1 °C to 52 °C.
• Not directly exposed to the sun.
• Installed in a dry place.
3.3.
Description and components location
3.4.
By-passing
If the system is equipped with a bypass and if a problem occurs, turn the valves to bypass the system as shown in the picture
below.
Normal operation
Softener System
In
6 / 40
3
/h
Display
Mixing device
Injector block
Out
Drain
Brine
Meter
Inlet
Outlet
In Bypass
Softener System
In
Out
Ref. MKT-UG-018 / A - 28.07.2017