As defined in the standard EN 60974-1, the duty cycle rate includes a time period of 10 minutes.
6 min.
For example, if a machine specified as 250A at %60 is to be operated at 250A, the machine can weld / cut
without interruption in the first 6 minutes of the 10 minutes period (zone 1). However, the following
4 minutes should be kept idle for the machine cool down (zone 2).
1.4 Technical Data
Mains Voltage (3-Phase 50-60 Hz)
TECHNICAL DATA
Rated Power
Welding Current Range
Rated Welding Current
Open Circuit Voltage
Dimensions (l x w x h)
Weight
Protection Class
Mains Voltage (3-Phase 50-60 Hz)
TECHNICAL DATA
Rated Power
Welding Current Range
Rated Welding Current
Open Circuit Voltage
Dimensions (l x w x h)
Weight
Protection Class
www.magmaweld.com
4 min.
6 min.
4 min.
6 min.
V
UNIT
kVA
ADC
ADC
VDC
mm
1170 x 528 x 1348 mm
kg
V
UNIT
kVA
ADC
ADC
VDC
mm
1170 x 528 x 1348 mm
kg
Technical Information
Time (min.)
4 min.
400
ID 350 MW ECO
18.92 (%40)
50 - 350
350
62
115.75
IP 23S
400
ID 500 MW ECO
31.81 (%40)
50 - 500
500
69
115.75
IP 23S