INSTALLATION INSTRUCTIONS
C-PHB-C-L2F-SCCT Series
With Emergency Backup
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
3.
SUITABLE FOR DAMP LOCATIONS.
CONVIENT AUX EMPLACEMENTS HUMIDES
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
CHAIN OR CABLE MOUNT
(FOR FIXTURES WITHOUT FACTORY INSTALLED
6FT CORD)
NOTE: Fixture must be suspended a minimum of 12" below mounting
surface.
1.
Attach support chains or cables (supplied by others or purchased
as Chain Kit Mounting Accessory) to the (2) supplied V-hooks.
2.
Insert the ends of the V-hooks through the larger slotted holes on
the top of the fixture and pass the ends of the hooks through the
smaller slotted holes at both ends of the fixture (See Figure 2).
To prevent V-hooks from disconnecting from the fixture, pinch the
ends of the V-hooks shut.
3.
Attach opposite ends of support chains or cables to mounting
surface. Make sure mounting surface and customer supplied
hardware can support the weight of the fixture.
4.
Remove screw from wiring access cover to allow for removal of
cover. See Figure 3 on next page.
5.
Conduit:
Insert leads from conduit through 1/2" knockout in wiring access
cover. Secure conduit to cover with conduit nut on opposite side of
the cover. See Figure 4.
6.
See Electrical Connections section for wiring.
following:
http://lighting.cree.com/warranty
Document
LPN00708X0002A0_A
Created By:
TMT
7.
Replace wiring access cover. Make sure both ends of wiring
access cover are engaged with the top of the back cover. Secure
cover in place using screw removed in Step 4.
8.
Select the desired CCT and wattage using the dip switches on the
fixture back cover. See Figure 5.
NOTE: Factory settings are highest wattage and 4500K.
CHAIN OR CABLE MOUNT (FOR FIXTURES WITH
FACTORY INSTALLED 6FT CORD)
NOTE: Fixture must be suspended a minimum of 12" below mounting
surface.
1.
Attach support chains or cables (supplied by other or purchased
as Chain Kit Mounting Accessory) to the (2) supplied V-hooks.
2.
Insert the ends of the V-hooks through the larger slotted holes on
the top of the fixture and pass the ends of the hooks through the
smaller slotted holes at both ends of the fixture. See Figure 2.
3.
Attach opposite ends of the support chains of cables to the
mounting surface. Make sure the mounting surface and customer
supplied hardware can support the weight of the fixture.
4.
See Electrical Connections section for wiring.
5.
Select the desired CCT and wattage using the dip switches on the
fixture back cover. See Figure 5.
NOTE: Factory settings are highest wattage and 4500K.
FIGURE 1
FIGURE 2
FIGURE 3
|
866.924.3645
Date:
1-19-2023
Back Cover

Publicité

loading

Sommaire des Matières pour C-LITE C-PHB-C-L2F-SCCT Serie

  • Page 1 Document LPN00708X0002A0_A Date: 1-19-2023 INSTALLATION INSTRUCTIONS Created By: C-PHB-C-L2F-SCCT Series Replace wiring access cover. Make sure both ends of wiring access cover are engaged with the top of the back cover. Secure With Emergency Backup cover in place using screw removed in Step 4. Select the desired CCT and wattage using the dip switches on the fixture back cover.
  • Page 2 Document LPN00708X0002A0_A Date: 1-19-2023 INSTALLATION INSTRUCTIONS Created By: C-PHB-C-L2F-SCCT Series With Emergency Backup FIGURE 4 PENDANT MOUNT (FOR FIXTURES WITHOUT FACTORY INSTALLED 6FT CORD) NOTE: Fixture must be suspended a minimum of 12" below mounting surface. Using a flat head screwdriver, remove the (2) outer 1/2" knockouts from the top surface of the fixture.
  • Page 3 Document LPN00708X0002A0_A Date: 1-19-2023 INSTALLATION INSTRUCTIONS Created By: C-PHB-C-L2F-SCCT Series With Emergency Backup FIGURE 8 EMERGENCY DRIVER CHECK NOTE: For short-term testing of the emergency function, the battery must be charged for at least one hour. The emergency driver must be charged for at least 24 hours before conduction a long-term test.
  • Page 4 Document LPN00708X0002A0_A Date: 1-19-2023 INSTALLATION INSTRUCTIONS Created By: C-PHB-C-L2F-SCCT Series With Emergency Backup WIRE GUARD ACCESSORY FIELD INSTALLED OCCUPANCY SENSOR Requires use of Wire Guard Accessory Kit ACCESSORY KIT Requires use of PIR Occupancy Sensor or Microwave Occupancy Sensor (120-277V only) Slide the wire guard over the bottom face of the fixture, making sure the screw attachment locations on the wire guard are positioned above the attachment holes on the fixture.
  • Page 5 Document LPN00708X0002A0_A Date : 19-01-2023 INSTRUCTIONS D’INSTALLATION Créé par : Série C-PHB-C-L2F-SCCT Replacez le couvercle d’accès au câblage. Assurez-vous que les deux extrémités du couvercle d’accès au câblage sont emboîtées avec le Avec secours d’urgence haut du couvercle arrière. Fixez le couvercle en place en utilisant la vis enlevée à...
  • Page 6 Document LPN00708X0002A0_A Date : 19-01-2023 INSTRUCTIONS D’INSTALLATION Créé par : Série C-PHB-C-L2F-SCCT Avec secours d’urgence FIGURE 4 MONTAGE EN SUSPENSION (POUR LUMINAIRES SANS CORDON INSTALLÉ EN USINE 1,83 m/[6 pi]) REMARQUE : Le luminaire doit être suspendu à 30,50 cm (12 po) en dessous de la surface de montage.
  • Page 7 Document LPN00708X0002A0_A Date : 19-01-2023 INSTRUCTIONS D’INSTALLATION Créé par : Série C-PHB-C-L2F-SCCT Avec secours d’urgence FIGURE 8 VÉRIFICATION DU PILOTE D’URGENCE REMARQUE : Pour effectuer un bref essai de la fonction d’urgence, la batterie doit être rechargée pendant au moins une heure. Le pilote pour l’éclairage d’urgence doit être rechargé...
  • Page 8 Document LPN00708X0002A0_A Date : 19-01-2023 INSTRUCTIONS D’INSTALLATION Créé par : Série C-PHB-C-L2F-SCCT Avec secours d’urgence ACCESSOIRE GRILLE DE PROTECTION JEU D'ACCESSOIRES DU CAPTEUR DE PRÉSENCE Nécessite l’utilisation de l'ensemble d’accessoires INSTALLÉ SUR PLACE grille de protection Nécessite l'utilisation d'un détecteur de présence infrarouge passif ou d'un détecteur de présence à...
  • Page 9 Documento LPN00708X0002A0_A Fecha: 19-01-2023 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-PHB-C-L2F-SCCT Vuelva a colocar la tapa de entrada de cables. Asegúrese de que ambos extremos de la cubierta de acceso a los cables estén con respaldo de emergencia enganchados con la parte superior de la cubierta trasera. Fije la tapa en su sitio con el tornillo que quitó...
  • Page 10 Documento LPN00708X0002A0_A Fecha: 19-01-2023 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-PHB-C-L2F-SCCT con respaldo de emergencia FIGURA 4 MONTAJE COLGANTE (PARA LUMINARIAS SIN CORDÓN DE 6 PIES INSTALADO DE FÁBRICA) NOTA: La luminaria debe estar suspendida a un mínimo de 12" debajo de la superficie de montaje.
  • Page 11 Documento LPN00708X0002A0_A Fecha: 19-01-2023 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-PHB-C-L2F-SCCT con respaldo de emergencia FIGURA 8 VERIFICACIÓN DEL CONTROLADOR DE EMERGENCIA NOTA: Para prueba a corto plazo de la función de emergencia, será necesario cargar la batería durante una hora como mínimo. Para realizar una prueba de largo plazo, será...
  • Page 12 Documento LPN00708X0002A0_A Fecha: 19-01-2023 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-PHB-C-L2F-SCCT con respaldo de emergencia KIT DE ACCESORIO DE SENSOR DE PRESENCIA ACCESORIO GUARDACABLES INSTALADO EN CAMPO Requiere el uso del kit de accesorios guardacables Requiere el uso del sensor de presencia PIR o el sensor de presencia de microondas (120-277 V Deslice la rejilla sobre la cara inferior de la luminaria, asegurándose únicamente)