C-LITE C-WP-A-RDC Serie Instructions D'installation

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS
C-WP-A-RDC Series
1L AND 3L
15L AND 20L
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This Product Must Be Installed In Accordance With The
Applicable Installation Code By A Person Familiar With
The Construction And Operation Of The Product And
The Hazards Involved.
Ce Produit Doit Être Installé Selon Le Code D'installation
Pertinent, Par Une Personne Qui Connaît Bien Le
Produit Et Son Fonctionnement Ainsi Que Les Risques
Inhérents.
3.
Suitable for wet locations.
Convient aux emplacements mouilles.
4.
Wall mount only.
Installation murale seulement
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
6L AND 10L
http://lighting.cree.com/warranty
Document:
LPN00675X0001A0_A
Created By:
TMT
MOUNTING OVER RECESSED JUNCTION BOX
NOTE: Knockouts are provided for mounting over 3" octagonal or 4"
octagonal boxes.
1. Remove lens assembly by loosening screws on side of frame.
Swing lens assembly open,disconnect quick connect wiring
connector(s) and lift lens assembly upward to remove from housing.
2. Drill out appropriate knockouts in back box for attachment to junction
box. Also drill knockout for wiring access.
NOTE: Fixture should not be exclusively supported by junction
box. Drill additional knockouts toward corners of fixture to provide
additional support. Do NOT drill within 1/4" (64 mm) from edges of
fixture.
3. Pull supply leads from junction box through wall of back box. Attach
back box to mounting surface using hardware (supplied by others)
appropriate for mounting surface.
NOTE: A high grade caulking material such as silicone rubber,
should be used around perimeter of back box to prevent water
leakage into fixture or junction box.
4. Make wiring connections per the Electrical Connections section.
5. Replace the lens assembly on hinges, re-connect quick-connect
wiring connectors, and swing lens into place. Re-tighten screws that
were loosened in Step 1.
WALL MOUNTED WITH CONDUIT FEED
1. Remove lens assembly by loosening screws on side of frame.
Swing lens assembly open,disconnect quick connect wiring
connector(s) and lift lens assembly upward to remove from housing.
2. Drill holes in four corners of back box to allow for attachment of
back box to mounting surface. Do NOT drill within 1/4" (64 mm)
from edges of fixture.
3. Attach back box to mounting surface using hardware (supplied by
others) appropriate for mounting surface.
NOTE: A high grade caulking material such as silicone rubber,
should be used around perimeter of back box to prevent water entry.
4. Remove appropriate threaded plugs on sides of fixture and route
electrical conduit to the holes desired. Feed the supply leads through
the conduit and into the back box.
NOTE: Use of teflon tape on the conduit threads will ensure a
watertight seal.
5. Make wiring connections per the Electrical Connections section.
6. Replace the lens assembly on hinges, re-connect quick-connect
wiring connectors, and swing lens into place. Re-tighten screws that
were loosened in Step 1.
ELECTRICAL CONNECTIONS
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply common to fixture neutral (white) lead.
3. Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply L1 (Hot) to fixture neutral (white) lead.
3. Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
1-800-236-6800
|
Date
12-11-2019

Publicité

Table des Matières
loading

Sommaire des Matières pour C-LITE C-WP-A-RDC Serie

  • Page 1 Document: LPN00675X0001A0_A Date 12-11-2019 INSTALLATION INSTRUCTIONS Created By: C-WP-A-RDC Series MOUNTING OVER RECESSED JUNCTION BOX NOTE: Knockouts are provided for mounting over 3" octagonal or 4" octagonal boxes. 1. Remove lens assembly by loosening screws on side of frame. Swing lens assembly open,disconnect quick connect wiring connector(s) and lift lens assembly upward to remove from housing.
  • Page 2: Installation Instructions

    Document: LPN00675X0001A0_A Date 12-11-2019 INSTALLATION INSTRUCTIONS Created By: C-WP-A-RDC Series FCC NOTICE CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 3: Medidas Importantes De Seguridad

    Documento: LPN00675X0001A0_A Fecha 12-11-2019 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-A-RDC INSTALACIÓN SOBRE UNA CAJA DE CONEXIONES EMPOTRADA NOTA: Incluye orificios prepunzados para instalarse sobre cajas de conexiones octagonales de 3” (76 mm) u octagonales o cuadradas de 4” (101 mm). 1.
  • Page 4: Conexiones Eléctricas

    Documento: LPN00675X0001A0_A Fecha 12-11-2019 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-A-RDC CONEXIONES ELÉCTRICAS AVISO DE LA FCC El dispositivo está equipado con un controlador universal de voltaje, PRECAUCIÓN: Los cambios o modificaciones que no se autoricen 120-277 V (es decir 120 V, 208 V, 240 V o 277 V) expresamente podrían invalidar la garantía del equipo.
  • Page 5: Mesures De Sécurité Importantes

    Document : LPN00675X0001A0_A Date 12-11-2019 INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-A-RDC MONTAGE AU-DESSUS D'UNE BOÎTE DE DÉRIVATION ENCASTRÉE REMARQUE : Des débouchures sont prévues pour le montage sur des boîtes de dérivation octogonales de 7,6 cm (3 po) ou octogonales de 10,2 cm (4 po) .
  • Page 6: Raccordements Électriques

    Document : LPN00675X0001A0_A Date 12-11-2019 INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-A-RDC RACCORDEMENTS ÉLECTRIQUES AVIS DE LA FCC Le luminaire est équipé d’un système d’entraînement de tension MISE EN GARDE : Les changements ou modifications non expressé- universelle de 120 à 277 volts (c'est-à-dire, 120 V, 208 V, 240 V ou 277 V) ment approuvés peuvent annuler votre droit à...

Table des Matières