Release Stroke function at the maximum power, proceed as follows:
ensure you have enabled Extended Menu 3 (blinking 1 1 1 0 1 1 1 0
of LED LEV) and then use the SEL key to select blinking LED L3 and
press the SET key; LED L3 becomes steady on and programming will
be completed. If you wish to enable the Release Stroke function at the
power set via the "FORCE" Trimmer, repeat the operation described
by pressing the SELECT key twice (LED L3 will blink rapidly) rather
than once. Repeat the procedure if you wish to restore the initial
configuration.
4. SLAM LOCK:
The control unit is factory set with the Slam Lock function disabled.
This function consists in adding, in the case of a deceleration stage
during closing, 1 extra second at the maximum power or at the
power selected with trimmer VR1, in such a way as to ensure positive
engagement of the gate lock, if installed. If you wish to enable the Slam
Lock function at the maximum power, proceed as follows: ensure you
have enabled Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV)
and then use the SEL key to select blinking LED L4 and press the SET
key; LED L4 becomes steady on and programming will be completed.
If you wish to enable the Slam Lock function at the power set via the
"FORCE" Trimmer, repeat the operation described above, pressing the
SEL key twice (LED L4 will blink rapidly) rather than once. Repeat the
procedure if you wish to restore the initial configuration.
5. PED CMD ELECTRIC LOCK ACTIVATION. (ELS/CMD PED):
The control unit is factory set with the function for electric lock activation
via the Pedestrian command disabled. The function for electric lock
activation with the Pedestrian command is used when, for example, the
application consists of a sliding gate with a pedestrian gate alongside.
With this function enabled the sliding gate can be opened both using
commands from the P/P Pushbutton and the remotes, and via the PED
commands from the pedestrian gate by activating the electric lock.
To enable this function proceed as follows: ensure you have enabled
Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV) and then use
the SEL key to select blinking LED L5 then press the SET key; LED L5
becomes steady on and programming will be completed. Repeat the
procedure if you wish to restore the previous configuration.
6. FLASHING LIGHT OPERATION/COURTESY LIGHT:
The control unit is factory set with Flashing Light during Pause Time
disabled. If you wish to enable this function proceed as follows: ensure
you have enabled Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED
LEV) and then use the SEL key to select blinking LED L6 and press
the SET key; LED L6 becomes steady on and programming will be
completed. Repeat the procedure if you wish to restore the previous
configuration.
Courtesy Light Operation: The 24 ~ 4W max. Courtesy Light
output will switch on for 3 minutes whenever an opening command
is transmitted
7. PREFLASHING/PAUSE FLASHING:
The control unit is factory set with the Preflashing and Pause Flashing
functions disabled. If you wish to enable the Preflashing function,
proceed as follows: ensure you have enabled Extended Menu 3
(blinking 1 1 1 0 1 1 1 0 of LED LEV) and then use the SEL key
to select blinking LED L7 and press the SET key LED L7 becomes
steady on and programming will be completed. If you wish to enable
the Pause Flashing function repeat the operation described above,
pressing the SET key twice (LED L7 will blink rapidly) rather than once.
Repeat the procedure if you wish to restore the initial configuration.
Preflashing Operation: The 110 ~ and 24V flashing light output
will always switch on 3 seconds before the gate starts the closing
operation..
Pause Flashing Operation: The 110 ~ and 24V Flashing Light output
will switch on if previously programmed The Pause Time.
RESET
If it becomes necessary to reset the control unit to restore the factory
settings, press the SEL and SET keys together; this will cause all the
RED indicator LEDs to light simultaneously followed immediately by the
control unit switching off.
28
COMUNELLO ®Copyright 2014 - All right reserved
DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle a functional test of the connected photocell is performed. In
the case of an open circuit and/or malfunctioning of the photocell,
the control unit does not enable movement of the gate and visually
signals the test failed condition by causing all the indicator LEDs to
blink simultaneously. As soon as correct operation of the photocell is
restored the control unit is ready for normal use. This operating mode
guarantees failure monitoring in compliance with EN 954-1 Category
2.
Commands input test:
In correspondence with each low voltage command input the control
unit is equipped with a signalling LED so that the status of the input can
be checked at a glance.
Operating logic: LED on input closed, LED off input open.
WARRANTY
Fratelli Comunello SpA provides a warranty for 24 months for the correct
functioning of the actuators from the date of manufacture, provided
that the performance specications indicated in the product instruction
manuals are respected. Free of charge repair and replacement of
components that are found to be faulty according to the indisputable
judgment of the company's technical staff shall be guaranteed at the
sole discretion of Fratelli Comunello Spa, and so excluding any claim
for damages made by others. Warranty material shall be returned to
Fratelli Comunello S.p.a. headquarters carriage paid and will then be
shipped to the customer carriage unpaid. The material found to be
faulty and returned to Fratelli Comunello S.p.a. shall remain property
of the Seller. Any cost resulting from any work needed to repair the
defect or to replace the material shall be charged to the Buyer. No
compensation shall be allowed for the period of device inactivity. Work
under warranty does not prolong the warranty period. The defect of
the product shall be reported by the Buyer within 8 (eight) days from
its discovery or from the date of delivery of the goods, under penalty
of invalidation of the warranty. Such claim shall be notied in writing.
Warranty does not cover:
Any product defect or damage that may have been incurred during
transport; any defect or damage arising from any fault and/or from
neglect, inadequacy and misuse of the electrical wiring in the Buyer's
property; any defect or damage caused by any repairs carried out
by non authorised personnel or by incorrect use/installation (with
reference to this, system maintenance is recommended every 6
months) or if not original spare parts are used; any defect caused by
chemicals or atmospheric conditions. The warranty does not cover
any cost neither for consumable materials nor for alleged defects or
convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to
continue changes and improvements; their technical features and
image may therefore change without previous notice.