With the brake enabled the control unit reduces coasting of the gate
due to inertia at the time of a stop or direction reversal command.
Repeat the procedure if you wish to restore the previous configuration.
2. DECELERATION:
As indicated above, the control unit allows a deceleration stage to
be programmed during opening and closing, while with the Automatic
Programming function the deceleration stage is included automatically.
However, if no deceleration stage is required it can be excluded. In
this manner, when using Automatic Programming the Deceleration
stage will no longer be included, while if the Motor Times Programming
function is used the option of programming a deceleration stage during
opening and closing will no longer be available. If, before excluding the
deceleration stage it had already been programmed using the Motor
Times Programming function, programming must be repeated from the
beginning. If you wish to exclude the deceleration stage proceed as
follows: ensure you have enabled Extended Menu 2 (blinking 1 1 0 1
1 0 of LED LEV) and then use the SEL key to select blinking LED L2
and press the SET key; LED L1 becomes steady on and the operation
will be completed. Repeat the procedure if you wish to restore the
previous configuration.
3. ALWAYS CLOSE:
The control unit allows to set "Always Close" operation: this function,
which is programmable only if a Pause Time has already been
programmed, is activated after a power loss; if the gate open condition
is confirmed a closing movement is started automatically, preceded
by 5 seconds of preflashing. If you wish to exclude the deceleration
stage proceed as follows: ensure you have enabled Extended Menu 2
(blinking 1 1 0 1 1 0 of LED LEV) and then use the SEL key to select
blinking LED L3 and press the SET key; LED L3 becomes steady on
and the operation will be completed. Repeat the procedure if you wish
to restore the previous configuration.
4. FOLLOW ME:
The control unit allows the "Follow me" function to be configured;
programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the DS1 photocell,
meaning the gate re-closes 5 seconds after transit of the user. To
activate this function, proceed as follows: ensure you have enabled
Extended Menu 2 (blinking 1 1 0 1 1 0 of LED LEV) and then use the
SEL key to select blinking LED L4 and press the SET key; LED L4
becomes steady on and the operation will be completed. Repeat the
procedure if you wish to restore the previous configuration.
5. PED. MOT. T: (Programming of pedestrian opening motor
time of max 4 minutes)
The control unit is factory set with Motor time (Pedestrian opening) of
10 seconds without deceleration.
If the pedestrian run time must be changed, programming must be
carried out with the gate closed as follows: ensure you have enabled
Extended Menu 2 (blinking 1 1 0 1 1 0 of LED LEV) use the SEL key
to select blinking LED L5 and then press the SET key momentarily;
the Operator will start the opening movement; when the required
deceleration starting point is reached, press the SET key again; LED
L5 will start blinking more slowly and the Operator will decelerate; on
reaching the required poisition press SET to terminate the Opening
cycle. At this point LED L5 returns to the normal blinking speed and
the Operator restarts in the Closing movement; repeat the operations
described above for the Closing movement.
If you do not require the control unit to perform the deceleration,
during programming, when the opening and closing cycle has been
completed press the SET key twice consecutively rather than just
once.
During programming, instead of the SET key on the control unit you
can use the button on the remote, providing the remote has been
saved beforehand.
6. AUXILIARY RADIO CHANNEL OPERATING LOGIC:
(2
CH monostable)
nd
The control unit allows the operating logic of the Auxiliary Radio
Channel to be selected.
The control unit is factory set with "Monostable" operation of the
Auxiliary Radio Channel. If you wish to enable "Bistable" operation
proceed as follows: ensure you have enabled Extended Menu 2
(blinking 1 1 0 1 1 0 of LED LEV) and then use the SEL key to select
blinking LED L6 and press the SET key; LED L6 becomes steady on
and the operation will be completed. If you wish to enable "3 Minutes
Timed" operation, repeat the operation described above; pressing the
SEL key twice (LED L6 will blink rapidly) rather than once. Repeat the
procedure if you wish to restore the initial configuration.
7. REMOTE RADIO CONTROL PROGRAMMING:
The control unit allows the transmission code to be programmed
remotely without acting directly on the control unit SEL key.
Remote programming of a Radio remote control is performed as
follows: send, continuously for a time in excess of 10 seconds, the
code of a previously saved remote control; at the same time the
control unit switches to programming mode as described above for
the LED L2 in the main menu. If a previously saved pedestrian code is
transmitted continuously the control unit will enter programming mode
of a new pedestrian code and LED L2 will blink as though acquisition
of the pedestrian code were active (1 1 0 1 1 0 1 1 0); if the code
is associated with the 2
nd
CH/AUX input the LED will blink as though
acquisition of the 2
CH code were active (1 1 1 0 1 1 1 0 1 1 1 0). To
nd
enable the remote programming function, proceed as follows:
ensure you have enabled Extended Menu 2 (blinking 1 1 0 1 1 0 of
LED LEV) and then use the SEL key to select blinking LED L7 and
press the SET key; LED L7 becomes steady on and the operation will
be completed. Repeat the procedure if you wish to restore the initial
configuration.
EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the
main menu functions.
If you wish to enable the functions described in Extended Menu 3,
proceed as follows: select blinking LED LEV and press SET 3 times.
The LED will start blinking alternately 1 1 1 0 1 1 1 0. This means there
will be 30 seconds to select the functions of Extended Menu 3 using
the SEL and SET keys; once an additional 30 seconds have elapsed
the control unit reverts to the main menu.
L1
SOFT STOP
L2
SOFT START
L3
RELEASE STROKE
L4
SLAM LOCK
L5
ELS / PED CMD
L6
FLASHING/COURTESY LIGHT
L7
PREFLASH/PAUSE FLASHING
LEV
MENU LEVEL
1. SOFT STOP:
The control unit is factory set with the Soft Stop function disabled. If
you wish to enable this function, proceed as follows: ensure you have
enabled Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV) and
then use the SEL key to select blinking LED L1 and press the SET key;
at the same time LED L1 becomes steady on and programming will
be completed. With the Soft Stop function enabled, at the end of the
movement the control unit will reduce operator force to zero gradually
in a 2 second interval. Repeat the procedure if you wish to restore the
previous configuration.
2. SOFT START:
The control unit is factory set with the Soft Start function disabled. If
you wish to enable this function, proceed as follows: ensure you have
enabled Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV) and
then use the SEL key to select blinking LED L2 and press the SET
key; LED L2 becomes steady on and programming will be completed.
With the Soft Start function enabled, at the start of each movement the
control unit will control start-up of the operator, gradually increasing
the force from the minimum to the value set by the "FORCE" trimmer
during the first 2 seconds of operation. Repeat the procedure if you
wish to restore the previous configuration.
Note: when the Soft Start function is enabled, the control unit
automatically disables the Starting Torque function, while if Soft Start is
disabled then Starting Torque is automatically enabled.
3. RELEASE STROKE:
The control unit is factory set with the release stroke function disabled.
This function comprises sending a closing command for 2 seconds
at the start of an opening cycle: this facilitates release of the lock to
allow correct execution of the opening cycle. If you wish to enable the
COMUNELLO ®Copyright 2014 - All right reserved
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
3 FLASHIES