SET Key: programs the information in accordance with the function
type preselected with the SEL key.
IMPORTANT: The SET key function can be replaced by the remote if
programmed beforehand (CODE LED on).
Programming enabled only when safety devices are not active
MAIN MENÙ
The control unit is factory set to allow the selection of several important
functions.
L1
STEP BY STEP
Step-by-Step
L2
CODE TX
Code entered
L3
CONDO
L4
MOTOR TIME
Programmed time
L5
PAUSE TIME
With automatic closing
L6
DELAY
L7
AUTOM PRG
LEV
MENU
1. STEP BY STEP:
In the default configuration the control unit is set with "Automatic"
operating logic enabled (LED n1 off); if the "Step-by-Step" operating
logic is required (LED n1 on), proceed as follows; use the SELECT
key to select blinking LED n1 and then press the SET key: LED n1
becomes steady on and programming will be completed.
If the "Step-by-Step 1" operating logic is required, repeat the operation
above described, by pressing the SEL key twice instead only one (to
obtain the quick blinking of LED. Repeat the procedure if you wish to
restore the previous configuration.
2. TX CODE: (Remote control code):
Up to 120 remotes with different codes of either the fixed or rolling
code type can be saved on the control unit.
Programming:
Programming of the transmission code is performed as follows: use
the SELECT key to select blinking LED L2. Press SET once; the LED
will change its blinking mode (longer 1 0 1 0) to show that the
first level is being saved. On sending the selected code with the
required remote, the CODE LED will remain steady on to indicate that
programming will be completed.
To save the code for pedestrian opening / single leaf, proceed as
follows: use the SELECT key to select blinking CODE LED L2. Press
SET twice consecutively; the LED will change its blinking mode (1 1 0
1 1 0) to show that
the pedestrian code is being saved. On sending the selected code
with the required remote, the CODE LED L2 will remain steady on to
indicate that programming will be completed.
To save the code for the 2nd AUX channel proceed as follows:
use the SELECT key to select blinking LED L2. Press SET 3 times
consecutively; the LED will change its blink mode (1 1 1 0 1 1 1 0) to
show that the 2nd AUX channel code is being saved. On sending the
selected code with the required remote, LED L2 will remain steady on
to indicate that programming will be completed.
If all 120 codes have been saved, repeating the programming operation
will cause all the programming LEDs to start blinking to signal that no
further codes can be saved.
Deletion:
Use SELECT to go to LED L2; activate blinking of the code to be
deleted (CODE or PEDESTRIAN or 2nd AUX channel as identified
by the associated blinking mode); press and hold down SET for >
5 s. After this interval, the LED will switch off for 2 seconds and the
procedure is completed. If all CODE and PEDESTRIAN codes are
deleted, the LED will remain off.
If only PEDESTRIAN or 2nd CH codes remain stored, the LED blinking
mode will change (1 1 1 1 0 1 1 1 1 0)
Rule of the first saved Remote control:
When programming remotes the following rule is applied: if the first
remote to be saved is a rolling code type, the receiver will subsequently
accept only rolling code remotes, thus providing enhanced anti-
intrusion security; if the first remote to be saved is a fixed code type,
the receiver will subsequently accept both fixed code remotes and
rolling code remotes.
Automatic
No code
ON
OFF
30 sec.
Without automatic closing
ON
OFF
ON
OFF
ON
3. CONDO:
The Condominium function means that during the opening movement
or during the pause time the control unit will not respond to commands
sent by Pushbuttons or remotes. In contrast, during the closing
movement a command sent by the Pushbuttons or the remotes will
reverse the direction of movement. This operating mode is invaluable
when the automation includes a loop detector.
In the default configuration the control unit is set with the Condominium
function disabled; if the Condominium function is required, proceed as
follows: use the SELECT key to select blinking LED L3 and then press
the SET key: LED L3 becomes steady on and programming will be
completed. Repeat the procedure if you wish to restore the previous
configuration.
4. MOTOR TIME (Operator run time programming, max 4
minutes):
The control unit is factory set with Operator run time of 30 seconds
without deceleration.
If the run time of Operators 1 and 2 must be changed, programming
must be carried out with the gate closed as follows: use the SEL key
to select blinking LED L4 and then press the SET key momentarily;
Operator 1 will start the opening cycle; when the required deceleration
starting point is reached, press the SET key again; LED L4 will start
blinking more slowly and Operator 1 will decelerate. On reaching the
required position, press SET to terminate the Opening cycle. At this
point LED L4 will revert to the normal blinking rate and Operator 2 will
start the opening cycle: repeat the run time programming operation for
Operator 2. When motor times programming for the opening cycle is
finished, Operator 2 restarts immediately in the closing cycle: repeat
the operations described above for the Closing cycle of Operator 2
followed by Operator 1.
If you do not require the control unit to perform the deceleration,
during programming, when the opening and closing cycles have been
completed press the SET key twice consecutively rather than just
once.
If the control unit is used in the single Operator configuration (dip switch
SW1 OFF), programming of the run time of Operator 2 is not executed.
During programming, instead of the SET key on the control unit you
can use the button on the remote, provided the remote has been
saved beforehand.
5. PAUSE TIME (Automatic closing time programming 4 min.
max.):
The control unit is factory set with automatic closing disabled. If you
wish to enable automatic closing proceed as follows: use the SEL key
to select blinking LED L5 and press the SET key momentarily; now
wait for a time equivalent to the required time; press the SET key again
momentarily and at the same time the automatic closing time will be
saved and LED L5 will remain steady on. If you wish to restore the initial
condition (no automatic closing) select blinking LED L5 and then press
the SET key twice consecutively in an interval of 2 seconds. The LED
will switch off and the operation will be completed.
During programming, instead of the SET key on the control unit you
can use the button on the remote, providing the remote has been
saved beforehand.
6. LEAVES DELAY (15 sec. max leaf delay programming):
The control unit is factory set with leaves opening and closing delay
disabled (4 sec.). If the control unit is used in the configuration for an
automation with 2 operators, it may be necessary to set a different
leaves delay time; programming must be performed with the gate
closed as follows: press the SELECT key to select blinking LED L6 then
press the SET key momentarily; now wait for a time equivalent to the
desired time interval and then press the SET key again momentarily, at
the same time the fixed 4 second leaves opening delay and the closing
delay for the programmed time will be saved and LED L6 will remain
steady on.
If you want to deactivate this function (without leaves delay), select
blinking LED L6 and then press the SET key twice consecutively in a
time interval of 2 seconds, at the same time the LED will switch off and
the operation will be terminated.
7. AUTOMATIC PROGRAMMING (PRG AUTOM):
The control unit allows Automatic Programming (SIMPLIFIED).
Press the SEL key to select blinking LED L7 and then press the SET
key and hold it down; Operator 2 will perform closing until reaching
the limit switch or end stop, thereafter the Operator 1 movement will
COMUNELLO ®Copyright 2014 - All right reserved
25