72'' ATLANTA Installation Instructions
Should the remote and receiver lose control after installation or during use, the pairing of the remote and the
receiver must be repaired. Below are the operating symptoms and method to repair the pairing of the DC
ceiling fan remote and receiver.
Issues:
Loss of control - Fan is only running at high speed after installation
Loss of control - No reverse function after installation
Loss of control - Remote cannot communicate with the receiver
Solution:
Switch off the main power of ceiling fan.
Switch on the main power of the ceiling fan. Press and hold the On/Off button on the remote for 5 seconds
within 30 seconds after switching on. There will be a notification 'beep' sound from the receiver to indicate
that the paring process is successful.
Turn on and select the different speed of the ceiling fan to check the operation of the fan.
WOBBLE:
NOTE: ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet. If the fan
was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimetres is quite acceptable
and DOES NOT suggest any problem.
TO REDUCE THE FAN WOBBLE: Please check that all screws which fix the mounting bracket.
BALANCING KIT: A balancing kit is provided to balance the ceiling fan on initial installation. Please refer to the instruction
on how to use the balancing kit. The balancing kit can be used to assist re-balancing should the ceiling fan become un-
balanced again. Store your balancing kit away after installation for future use if required.
NOISE:
When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and
frequency signals superimposed in the electricity for off-peak hot water control, may cause a change in fan
motor noise. This is normal. Please allow a 24-hour "breaking -in" period, most noises associated with a new
fan disappear during this time. All electric motors are audible to some extent. Please note that this is not a
product fault, and as such is not covered under warranty.
NOTE: Always turn OFF the power at the mains switch before performing any maintenance or
attempting to clean your fan.
1) Every 6 months periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush
or lint free cloth to avoid scratching the paint finish. Please turn OFF electricity power when you do so.
2) Do not soak or immerse your ceiling fan in water or other liquids. It could damage the motor or the blades
and create the possibility of an electrical shock.
3) Ensure that the fan does not come in contact with any organic solvents or cleaners.
4) To clean the fan blade, wipe with only a damp clean cloth with NO organic solvents or cleaners.
5) The motor has a permanently lubricated ball bearing so there is no need to oil.
9 | P a g e
AFTER INSTALLATION
CARE & CLEANING

Publicité