11.
COMMON ERRORS / ERRORES COMUNES / ERREURS COMMUNES / GLI ERRORI PIU COMUNI / HÄUFIGE
FEHLER / VEELVOORKOMENDE FOUTEN
ERRO CODE
A) electricity not connected
B) power switch not turn on
C) pcb no power or broken
NO DISPLAY
D) signal wire not connected
E) computer broken
F) background light broken
NOT DISPLAY ALL
A) display drive IC not inserted well
INFORMATION
B) EMI gasket slip, not well fastened
A) driving position has resistance
NOT RUN
B) running belt too tight or too loose
SMOOTHLY
C) pcb torque too big or too small
---OR----
A) safety key off
(OR E00/E07)
B) magnetron not fixed well
A) signal wire not well connected
B) signal wire broken
E01/E13
C) signal wire broken
D) pcb broken
A) motor wire not well connected, or open
E02
circuit
B) IGBT on pcb broken
C) input voltage too low
A) speed signal wire not well connected,
E03
or sensor broken
B) pcb broken
A) incline motor wire not well connected
E04
B) incline motor broken
C) pcb broken
A) over-loaded
B) driving position hinder
E05
C) motor short circuit
D) pcb burnt
A) motor wire not well connected
E06
B) motor open circuit
C) motor idling
A) storage IC not well inserted
E08
B) storage IC broken, or pcb broken
A) machine stand or not put evenly on
E09
floor
B) pcb broken
A) pcb torque too big
E10
B) motor short circuit
C) driving position hinder
E11
Input voltage too big
E14
Input voltage too low
REASON
Connect the electricity
Turn on power switch
Press over-load protector or change new pcb
Re-connect signal wire or change new one
Change new computer
Check background light wire or change new one
Re-insert IC,and re-weld it or change new one
Re-assemble screen
Adjust driving position, or add some silicon oil
Adjust the belt tension
Ajust torque to right position
Put on safety key
Fix magnetron to right position
Re-connect signal wire
Change new signal wire
Change new computer
Change new pcb
Re-connect motor wire or change new motor
Change new pcb
Stop using, ask electrician to check
Re-connect speed signal wire or change new sensor wire
Change new pcb
Re-connect incline motor wire
Change new incline motor
Change new pcb
Turn off and re-start machine
Adjust driving position, or add oil
Change new motor
Change new pcb
Re-connect motor wire
Change new motor
Re-assemble to test
Re-insert IC, pay attention to pins
Change new IC, or change new pcb
Put evenly on floor
Change new pcb
Adjust torque to right position
Change new motor
Adjust driving position, or add oil
Stop using, ask electrician to check
Stop using, ask electrician to check
HOW TO SOLVE
FYTTER |WWW.FYTTER.COM