Notes on digital operation
• The operating instructions for your central unit will give
you exact procedures for setting the different parameters.
• The values set at the factory have been selected for mfx
in order to guarantee the best possible running characte-
ristics.
Adjustments may have to be made for other operating
systems.
• The setting done at the factory does not permit operation
with opposite polarity DC power in the braking block.
If you want this characteristic, you must do without
conventional DC power operation (CV 29/Bit 2 = 0).
mfx Protocol
Addresses
• No address is required; each decoder is given a one-
time, unique identifier (UID).
• The decoder automatically registers itself on a Central
Station or a Mobile Station with its UID.
• Name set at the factory: 6306 MAINZ T3
Programming
• The characteristics can be programmed using the
graphic screen on the Central Station or also partially
with the Mobile Station.
• All of the Configuration Variables (CV) can be read and
programmed repeatedly.
• The programming can be done either on the main track or
the programming track.
• The default settings (factory settings) can be produced
repeatedly.
12
All manuals and user guides at all-guides.com
• Function mapping: Functions can be assigned to any of
DCC Protocol
Addresses
• Possible addresses: short, long, and m.u. address
• Address range:
• Every address can be programmed manually.
• A short or a long address is selected using the CVs.
• A multiple unit address that is being used deactivates the
Programming
• The characteristics can be changed repeatedly using the
• The CV numbers and the CV values are entered directly.
• The CVs can be read and programmed repeatedly. (Pro-
• The CVs can be programmed, as you desire. PoM (Program-
• The default settings (factory settings) can be produced
• 14 or 28/126 speed levels can be set.
• All of the functions can be controlled according to the
the function buttons with the help of the 60212 Central
Station (with limitations) and with the 60213/60214/60215
Central Station (See help section in the Central Station).
1 – 127 (short address, m.u. address)
1 – 10239 (long address)
standard address.
Configuration Variables (CV).
gramming is done on the programming track.)
ming on the layout track) is only possible with those CVs
marked in the CV table. PoM must be supported by your
central controller (see the instructions for your controller).
repeatedly.