4.4) ERRORS:
these appear during operation, combined with a beep and flashing LED Worklights,
to notify the operator of procedural or operational errors.
Message
Error description
The pressure release button (2)
ERROR
was pressed before the control
ERROR
parameters were reached (Force/
ERROR
Pressure).
ERROR
Abnormal power consumption
ERROR
of the motor for more than 3
001
seconds.
001
The tool stops.
001
001
002
002
Output voltage of the pressure
001
002
transmitter is out of the pre-set
002
range.
003
003
002
Failure to reach the set pressure
003
003
within 30 seconds of continuous
004
004
operation of the machine.
003
004
Overcharging of the battery with
004
protection tripping.
004
The tool stops.
Errors are displayed for about 30 seconds before being reset, but will display repeatedly in
the event of permanent anomalies.
5. CONNECTION TO COMPUTER
The memory card integrated in the tool records operating data from 200.000 cycles for transfer via
the USB cable supplied.
To view and manage this data, go to www.cembre.com and register in the dedicated area, then
download the free Cembre software CEM_SWBT01.
Keeping the Firmware of the tool updated, via free of charge download from here, will optimise
the tool's performance.
6. RETURN TO Cembre FOR OVERHAUL
In the case of a breakdown contact our Area Agent who will advise you on the problem and give
you the necessary instructions on how to dispatch the tool to our nearest service Centre; if possible,
attach a copy of the Test Certificate supplied by Cembre together with the tool or fill in and attach
the form available in the "ASSISTANCE" section of the Cembre website.
Solution
Repeat the work cycle and wait for the
motor to stop automatically.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery,
then re-start the tool.
If the error occurs frequently, contact
Cembre.
Repeat the work cycle; if the error
occurs frequently, contact Cembre.
Repeat the work cycle; if the error
occurs frequently, contact Cembre.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery,
then re-start the tool.
If the error occurs frequently, contact
Cembre.
12