l. Repair interventions of the hermetic components
be disconnected from the appliance running, before the eventual removal of the
hermetic covers, etc.
Whenever it is absolutely necessary to have electric power supply for the unit
during maintenance, a constantly active leak detector must be positioned in the
most critical point in order to signal a potentially dangerous situation.
intervention on electric components, the housing is not altered in a way to affect
the level of protection.
This includes damage to cables, excessive number of connections, terminals not
incorrect installation of the closing devices, etc.
leak detection equipment.
Intrinsically safe components do not have to be isolated before working on
them.
2.3 - DATA TABLE
2.4 - SELECTION OF POSITION OF THE INSIDE UNIT
To obtain the best operating performance and prevent faults or hazardous conditions, the position of indoor
unit installation must meet the following requirements:
a. Do not expose the indoor unit to heat or steam.
b. Make sure that the space to the right and left is at least 120 mm and space above the unit is at least 150
c. The indoor unit must be installed at a minimum height of 2 metres and maximum of 3 metres from the
d
e. There must be no obstacles for the free circulation of air both from the inlet side and especially the outlet
side. In particular, there must be no obstacles within a distance of 2000 mm.
A shorter distance could cause turbulence such to prevent correct operation of the appliance.
f. If possible, install the unit on an outdoor wall, in a way to be able to convey condensate draining to the
outside.
g
EN - 15