AC TRUE RMS CURRENT MEASUREMENT
WARNING:
Ensure that the test leads are disconnected from the meter before making current measure-
ments.
1
Set the function switch to 1000 A or 400 A or 40 A range position. and make sure that the current
under test does not exceed the upper limit of the measuring range you have selected.
2
Press the [ MODE ] button to select the AC Cur-
rent range. The meter automatically defaults to DC
Current.
3
Press the trigger to open up the transformer jaws and
clamp ground the single conductor under test.
4
Read the display.
Note:
During current measurements keep the transformer
•
jaws fully closed. otherwise this will affect the
accuracy of the measurement.
When large currents the transformer jaws may buzz.
•
This is not a fault and does not affect the accuracy
of the reading.