en-us_main.book.book Page 16 Wednesday, January 25, 2023 8:53 AM
16 INSTALLATION
NOTE
• The best location for the electrical conduit is on
the right side of the back wall. Re-route the
electrical cable before installation if the electrical
conduit pipe is longer than 3" (76 mm) and is
centered on the back wall.
1
Turn off electrical power to the unit at the
circuit breaker.
2
Use a Phillips screwdriver to remove the
screw from the junction box cover and
remove the cover.
3
Use a Phillips screwdriver to remove 2 screws
a
.
4
Remove the junction box from the appliance.
5
Insert a 3/8" strain relief
in the junction box. Tighten the ring nut
secure it in place.
6
7
8
b
through the hole
c
to
Insert the electrical cable through the hole in
the strain relief. Tighten 2 screws to secure
the cable.
Pull the existing wires through the openings
in the junction box. Tighten 2 screws
reassemble the junction box in the appliance.
Pair the white, black, and green wires to the
matching colored wires from the dishwasher.
Then twist on the provided wire nuts
to connect the corresponding wires.
d
to
e
tightly