Télécharger Imprimer la page

Panasonic S C09 3E8 Serie Mode D'emploi page 30

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 224
29. Tank re-heat temp.
Set temp to perform reboil of tank water.
(When boiled by heat pump only, (51°C – Tank re-heat temp) shall become
max temp.)
Setting range is -12°C ~ -2°C
30. Sterilization
Set timer to perform sterilization.
1 Set operating day & time. (Weekly timer format)
2 Sterilization temp (55~75°C  If use back-up heater, it is 65°C)
3 Operation time (Time to run sterilization when it reached setting temp
5min ~ 60min)
User shall set whether to use or not to use sterilization mode.
3-5. Service Setup
31. Pump maximum speed
Normally setting is not necessary.
Please adjust when need to reduce the pump sound etc.
Besides that, it has Air Purge function.
32. Pump down
Operate pump down operation
33. Dry concrete
Operate concrete curing operation.
Select Edit, set temp for every stage (1~99 1 is for 1 day).
Setting range is 25~55°C
When it is turned ON, dry concrete starts.
When it is 2 zone, it dries both zones.
34. Service contact
Able to set name & tel no. of contact
person when there is breakdown
etc. or client has trouble. (2 items)
30
ACXF60-03130_EN ES IT.indb 30
ACXF60-03130_EN ES IT.indb 30
Initial setting: -8°C
Initial setting: 65°C 10min
Initial setting: Depend on model
Service setup
Pump down:
ON
Service setup
Service contact:
Contact 1
Contact 2
Select
Service setup
Flow rate
88:8 L/min
Select
17:26, Wed
Service setup
Pump down:
Confi rm
45°C
40°C
35°C
30°C
1
2
3
4
17:26, Wed
Contact-1: Bryan Adams
A B C D E F G H I J K L M N O P Q R
S T U V W X Y Z
j k l m n o p q r s t u v w x y z
Confi rm
Select
-12°C ~ -2°C
①  ③
17:26, Wed
Max. Duty
Operation
Air Purge
0xCE
17:26, Wed
Pump down operation
in progress!
ON
OFF
Confi rm
40°C
35°C
5
6
Stage
ABC/ abc
0-9/ Other
a b c d e f g h i
Enter
9/22/2016 4:21:42 PM
9/22/2016 4:21:42 PM

Publicité

loading

Ce manuel est également adapté pour:

S c12 9e8 serieS c16 9e8 serie