Enclosure
Double molded, waterproof IP67
Shock resistance
2 meters (Drop Test)
Diode Test
Test current of 0.9mA maximum, open circuit
voltage 2.8V DC typical
Continuity Check
Audible signal will stop if the resistance is
>100Ω, test current < 0.35mA
Input Impedance
>10MΩ VDC = and V ≈
AC Response
Averaging
ACV Bandwidth
40Hz to 1000Hz
Peak Factor
≤ 3 at full scale up to 500V, decreasing
linearly to ≤1.5 at 1000V
Display
6,000 count backlit with bargraph
Overrange indication
"OL" is displayed
Auto Power Off
15 min (approx.) with disable feature
Polarity
Automatic
no indication for positive values,
minus (-) sign for negative values
Measurement Rate
2 times per second, nominal
Low Battery Indication "
" is displayed if battery voltage drops
below operating voltage
Battery
1 x 9 V battery (6LF22)
Fuses
mA, µA ranges; 0.8A/1000V fast ceramic; F
A range; 10A/1000V fast ceramic
Operating Temperature 5°C to 40°C
Storage Temperature
-20°C to 60°C
Operating Humidity
max 80% up to 31°C decreasing linearly to
50% at 40°C
Storage Humidity
< 80%
Operating Altitude
2000 m maximum
Weight
342 g (incl. holster)
Size
187 x 81 x 50mm (incl. holster)
Safety
Double insulation per EN61010-1 to
Category IV 600V and Category III 1000V;
pollution Degree 2
32