Chapter II
Function
Range
Resolution
600 Ω
0.1 Ω
Resistance
6 kΩ
0.001 kΩ
60 kΩ
0.01 kΩ
600 kΩ
0.1 kΩ
6 MΩ
0.001 MΩ
60 MΩ
0.01 MΩ
Capacitance
60 nF
0.01 nF
600 nF
0.1 nF
6 μF
0.001 μF
60 μF
0.01 μF
600 μF
0.1 μF
1 000 μF
1 μF
Frequency
9.999 Hz
0.001 Hz
(electronic)
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
999.9 kHz
0.1 kHz
9.999 MHz
0.001 MHz
Sensitivity :
0.8 Veff. min. @ 20 % to 80 % duty cycle and
F < 100 kHz ;
5 Veff min. @ 20 % to 80 % duty cycle and
F > 100 kHz
Frequency
10.00-400 Hz 0.01 Hz
(electrical)
Sensitivity : 15 Vrms
Duty cycle
0.1 to 99.9 % 0.1 %
Pulse width : 100 µs - 100 ms
Frequency : from 5 Hz to 150 kHz
-45 to 400°C
-50 to +752°F
Temp.
(K type)
400 to 750°C
752 to 1382°F
(1)
: (probe accuracy not included)
Accuracy features consist in two elements:
(% reading R): is the accuracy of the measurement circuit
(+ digits D): is the accuracy of the analog to digital converter
DMM220
Authorized
Accuracy
overload
protection
±(0.3 % R + 4 D)
±(0.5 % R + 20 D)
±(3.5 % R + 4 D)
±(5 % R + 5 D)
±(0.1 % R + 1 D)
±(0.5 % R)
±(1.2 % R + 2 D)
±
(1)
0.1°C
(3.0%R + 5°C)
0.1°F
±
(1)
(3.0%R + 9°F)
(1)
±(2.5%R+1.8°C)
1°C
(1)
±(2.5%R+3.6°F)
1°F
1 000 V
1 000 V
1 000 V
1 000 V
1 000 V
1 000 V