5
Troubleshooting
Symptom
1. After repeated
a. Defective ignitor.
triggering of the red
or black piezo button,
b. Defective pilot or
the spark ignitor will
misaligned electrode
not light the pilot.
(spark at electrode).
c. No gas or low gas
pressure.
d. No LP in tank.
2. The pilot will not
a. Defective
f i r e - p a r t s . c o m
stay lit after carefully
thermocouple.
following the lighting
instructions.
b. Defective valve.
3. The pilot is
a. ON/OFF switch or
burning, there is no
wires defective.
gas burner, the valve
knob is in the ON
position, and the
ON/OFF switch is in
b. Thermopile may
the ON position.
not be generating
sufficient millivoltage.
c. Defective valve.
d. Plugged burner
orifice.
e. Wall switch or
wires are defective.
36
With proper installation, operation, and maintenance your gas fireplace will
provide years of trouble-free service. If you do experience a problem, this
troubleshooting guide will assist a qualified service person in the diagnosis
of a problem and the corrective action to be taken. This troubleshooting
guide can only be used by a qualified service technician.
Possible Cause
Check the spark at the electrode and pilot. If no spark and electrode wire is
properly connected, replace the ignitor.
Using match, light the pilot. If the pilot lights, turn off the pilot and trigger the red or
black piezo button again. If the pilot lights, an improper gas/air mixture caused the
bad lighting and a longer purge period is recommended. If the pilot will not light,
ensure the the gap at the electrode and pilot is one-eighth (1/8) inch to have a
strong spark. If the gap is OK, replace the pilot.
Check the remote shut-off valvess from the fireplace. Usually, there is a valve near
the gas main. There can be more than one (1) valve between the fireplace and the
main.
Check the LP (propane) tank. You may be out of fuel.
Check that the pilot flame impinges on the thermocouple. Clean and/or adjust the
pilot for maximum flame impingement.
Ensure that the thermocouple connection at the gas valve is fully inserted and tight
(hand tighten plus 1/4 turn).
Disconnect the thermocouple from the valve, place one millivolt meter lead wire on
the tip of the thermcouple and the other meter lead wire on the thermocouple
copper lead. Start the pilot and hold the valve knob in. If the millivolt reading is less
than 15mV, replace the thermocouple.
If the thermocouple is producing more than 15 millivolts, replace faulty valve.
Check the ON/OFF switch and wires for proper connections. Place the jumper
wires across the terminals at the switch. If the burner comes on, replace the
defective switch. If the switch is OK, place the jumper wires across the switch wires
at the gas valve. If the burner comes on, the wires are faulty or connections are
bad.
If the pilot flame is not close enough physically to the thermopile, adjust the pilot
flame.
Be sure the wire connections from the thermopile at the gas valve terminals are
tight and that the thermopile is fully inserted into the pilot bracket.
Check the thermopile with a millvolt meter. Take the reading at TH-TP&TP
terminals of the gas valve. The meter should read 325 millivolts minimum, while
holding the valve knob depressed in the pilot position, with the pilot lit, and the
ON/OFF switch in the OFF position. Replace the faulty thermopile if the reading is
below the specified minimum.
With the pilot in the ON position, disconnect the thermopile leads from the valve.
Take a reading at the thermopile leads. The reading should be 325 millivolts
minimum. Replace the thermopile if the reading is below the minimum.
Turn the valve knob to the ON position. Place the ON/OFF switch in the ON
position. Check the millivolt meter a the thermopile terminals. The millivolt meter
should read greater than 125mV. If the reading is acceptable, and if the burner
does not come on, replace the gas valve.
Check the burner orifice for stoppage. Remove stoppage.
Follow the corrective action in Symptom and Possible Cause 1.a above. Check
the switch and wiring. Replace where defective.
Quadra-Fire Village Collection • QVI30, QVI35 • 340-901EF Rev. B • 2/06