Step 7. Carefully lift the assembly and rest the
hanger ball of downrod assembly on the hanger
bracket attached to the outlet box. Be sure the
groove in the hanger ball is lined up with the
tab on the hanger bracket. (Fig.9)
Hanger
bracket
Hanger
ball
Tab
Groove
OK
Figure 9
Make the Electric
Connections
WARNING:To avoid possible electrical shock,
be sure electricity is turned off at the main fuse
box before wiring.
WARNING: Fan must be installed at a maximum
distance of 20 feet from the transmitting unit for
5.
All manuals and user guides at all-guides.com
proper signal transmission between the transmitting
unit and the fan's receiving unit. If you feel you do
not have enough electrical wiring knowledge or
experience, have your fan installed by a licensed
electrician.
Step 1. Connect green wires from EMI filter and
related parts according to the wiring diagram as
shown in Figure 11, make sure EMI filter is properly
seated in outlet box.
Step 2. Place the EMI filter into the ceiling box
before installing the receiver into the bracket. Insert
the receiver into the mounting bracket with the flat
side of the receiver facing the ceiling. (Fig. 10)
Step 3. Motor to receiver electrical connections:
Connect the grey wire from the fan to the grey wire
from the receiver. Connect the red wire from the fan
NO
to the red wire from the receiver. Connect the yellow
wire from the fan to the yellow wire from the
receiver. Connect the blue wire from the fan to the
blue wire from the receiver. Connect the white wire
from the fan to the white wire from the receiver.
(Fig.11)
EMI filter
Figure 10
Step 4. Receiver to house supply wires electrical
connections: Connect the black (hot) wire from the
ceiling to the black wire marked "AC IN L" from the
receiver. Connect the white (neutral) wire from the
ceiling to the white wire marked "AC IN N" from
the receiver. (Fig.11)
Secure all wire connections with the plastic wire
nuts provided.
AC IN L(Black)
AC IN N(White)
Ground wire
Ground wire
Ground wire
Ground wire
Red
Gray
Yellow
Ground wire
Hanger bracket
Figure 11
Gray
White
Yellow
Blue
Blue
Red
White