Your Eco-Aire heater comes pre-assembled with
the exception of the Spark Suppressor that needs
to be attached to the rear of the unit on the ex-
haust outlet.
DO NOT OPERATE THIS HEATER WITH THE SPARK SUP-
PRESSOR REMOVED!
Using the hardware and gasket supplied, attach
the suppressor to the rear of the unit as shown in
the illustration.
Read this entire manual before you install and use your Pellet heater. Failure to follow instructions may
result in property damage, bodily injury, or even death!
Before installing your heater, you must perform an initial burn in an OUTSIDE environment. Follow the Start-
Up Procedure in the Operation section of this manual.
Your Eco-Aire heater may be installed to code in either a conventional or mobile home (see SPECIAL MOBILE
HOME REQUIREMENTS).
It is recommended that only a authorized technician install your heater, preferably a National Fireplace Institute
(NFI) certified specialist.
This heater must be installed through an opening on an exterior wall. The heater may be installed in an existing
window or opening cut through a wooden, brick, or masonry wall.
Once the desired location is selected, and before cutting a hole, check the outside of the structure for
anything obstructing clearances to the exhaust vent. Also clear away leaves, shrubs/bushes, or trees that may
be around the exhaust outlet.
VENT TERMINATION CLEARANCES:
A) Minimum 4-foot [1.2m] clearance below or
beside any door or window that opens.
B) Minimum 1-foot [0.3m]clearance above any
door or window that opens.
C) Minimum 2-foot [0.6m] clearance from any
adjacent building.
D) Minimum 7-foot [2.1m] clearance from any
grade when adjacent to public walkways.
E) Minimum 2-foot [0.6m] clearance above any
grass, plants, or other combustible materials.
F) Minimum 4-foot [1.2m] clearance from an
forced air intake of any appliance.
G) Minimum 2-foot [0.6m] clearance below eves
or overhang.
H) Minimum 1-foot [0.3m] clearance horizontally
from combustible wall.
NOTICE: This unit shall be installed in such a way that the exhaust gases are directed so they do not jeopardize
people, overheat combustible structures, or enter buildings.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of a heater due to improper venting or installation. Call (800) 750-2723 and/or consult a
professional installer if you have any questions.
6
All manuals and user guides at all-guides.com
Assembly
Installation
INSTALL VENT AT CLEARANCES SPECIFIED ABOVE.
Ussc