UNIT PREPARATION
After properly installing your heater, you will need to perform the following steps before operation:
• Attach the electrical cord to the left side blower housing first; then plug it into a 110-volt outlet (an outlet
surge protector is highly recommended).
PERFORMING AN INITIAL BURN
You must perform an initial burn in this appliance before installing it in your home or garage. This process is to
ensure that the appliances is functioning correctly, to cure the high temperature paint and burn off any oil
that is present in the sheetmetal components of the combustion chamber. For the initial burn, only add a small
amount of fuel, approximately 4-5 lbs. or about the amount to fill a 2 lb. coffee can. Operate the appliance
on the 3 or 4 heat setting for approximately 30 minutes to an hour. There will probably be a small amount of
smoke or fumes irradiating from the appliance during this process. Follow the Start-Up procedure below to
begin your burn.
START-UP PROCEDURE
 Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or
"freshen up" a fire in this heater. Keep all such liquids well away from the heater while it is in use.
1. Verify that the hopper is clean and free of foreign matter.
2. Fill the hopper with wood pellets; do not allow any part of the bag or any other foreign material into the
hopper, as this may jam the auger.
3. Ensure that all pellet matter is cleared from the hopper seating surface.
4. Close the hopper lid. The unit WILL NOT feed fuel with the hopper lid open.
5. Verify that there is no pellet fuel, ash, or foreign matter in the burn-pot before starting the appliance.
6. Make sure that the viewing door and combustion door is securely closed (the safety switch will not allow
the heater to feed fuel if they are left open.
7. Press the "ON" button on the control pad and set the "HEAT RANGE" to your desired setting. The ON light
will be flashing and the light corresponding with the heat setting will be light.
What will happen next....
The heater will begin to feed fuel and the exhaust (draft) blower is running. Note that the exhaust blower is
pulsing. The auto-start ignitor will ignite the fuel in approximately 5-10 minutes. In the start-up mode, the "ON"
LED will flash until it reaches a factory preset temperature. At that point, the "ON" LED will come on solid and
the heater will begin to ramp up to your selected heat range.
The Room Air Blower will not function until the heater reaches a factory preset temperature.
SHUT DOWN PROCEDURE
WARNING: Never shut down this unit by unplugging it from the power source.
Press the "OFF" button on the control pad to put the stove in shut down mode. At this time, the red light above
the OFF will blink and the "ON" light will go off. The auger will stop feeding pellets, but the distribution blower
and exhaust blower will continue to operate. When the internal temperature of the unit drops below the fac-
tory preset temperature, the distribution blower and exhaust blower will cease to operate. The red light will
then shut off and the unit will be completely shut down.
The hotter the unit is during its operation, the longer it will take for the stove to complete the shut down cycle.
If the stove stays on for more than 1 hour after pressing the "OFF" button and you are sure that the fire is out,
the stove can be unplugged from the outlet. After approximately 10 seconds, the unit can be re-connected
to the power source and the control board will be reset.