SWIMMING POOL HEAT PUMP TYPE PV
6.2 CABLE SPECIFICATION
(1) Single phase unit
Nameplate maximum current
Phase line
Earth line
No more than 10A
2×1.5mm
2
10~16A
2×2.5mm
2
16~25A
2×4mm
2
25~32A
2×6mm
2
32~40A
2×10mm
2
40 ~63A
2×16mm
2
63~75A
2×25mm
2
75~101A
2×25mm
2
101~123A
2×35mm
2
123~148A
2×50mm
2
148~186A
2×70mm
2
186~224A
2×95mm
2
(2) Three phase unit
Nameplate maximum current
Phase line
Earth line
No more than 10A
3×1.5mm
2
10~16A
3×2.5mm
2
16~25A
3×4mm
2
25~32A
3×6mm
2
32~40A
3×10mm
2
40 ~63A
3×16mm
2
63~75A
3×25mm
2
75~101A
3×25mm
2
101~123A
3×35mm
2
123~148A
3×50mm
2
148~186A
3×70mm
2
186~224A
3×95mm
2
When the unit will be installed at outdoor, please use the cable which can against UV.
6.3 COMPARISON TABLE OF REFRIGERANT SATURATION TEMPERATURE
Pressure (MPa)
0
0.3
0.5
Temperature (R410A)(°C)
-51.3
-20
-9
Temperature (R32)(°C)
-52.5
-20
-9
Pressure (MPa)
2.5
2.8
3
Temperature (R410A)(°C)
43
47
51
Temperature (R32)(°C)
42
46.5
49.5
36
WWW.NORSUP.EU
MCB
Creepage protector
Signal line
1.5mm
20A
30mA less than 0.1 sec
2
2.5mm
32A
30mA less than 0.1 sec
2
4mm
40A
30mA less than 0.1 sec
2
6mm
2
40A
30mA less than 0.1 sec
10mm
2
63A
30mA less than 0.1 sec
16mm
80A
30mA less than 0.1 sec
n×0.5mm
2
25mm
100A
30mA less than 0.1 sec
2
25mm
125A
30mA less than 0.1 sec
2
35mm
2
160A
30mA less than 0.1 sec
50mm
2
225A
30mA less than 0.1 sec
70mm
250A
30mA less than 0.1 sec
2
95mm
280A
30mA less than 0.1 sec
2
MCB
Creepage protector
Signal line
1.5mm
20A
30mA less than 0.1 sec
2
2.5mm
32A
30mA less than 0.1 sec
2
4mm
40A
30mA less than 0.1 sec
2
6mm
2
40A
30mA less than 0.1 sec
10mm
2
63A
30mA less than 0.1 sec
16mm
80A
30mA less than 0.1 sec
n×0.5mm
2
25mm
100A
30mA less than 0.1 sec
2
25mm
125A
30mA less than 0.1 sec
2
35mm
2
160A
30mA less than 0.1 sec
50mm
2
225A
30mA less than 0.1 sec
70mm
250A
30mA less than 0.1 sec
2
95mm
280A
30mA less than 0.1 sec
2
0.8
1
1.3
1.5
1.8
2
4
11
19
24
31
35
3.5
10
18
23
29.5
33.3
3.3
3.5
3.8
4
4.5
5
55
57
61
64
70
74
53.5
56
60
62
67.5
72.5
Alterations which serve the technological progress as well as errors excepted!
SWIMMING POOL HEAT PUMP TYPE PV
2
2
NOTES
2.3
39
38.7
5.5
80
77.4
Alterations which serve the technological progress as well as errors excepted!
EN
DE
EN
NL
DE
FR
DK
SE
ORIGINAL MANUAL NORSUP