Télécharger Imprimer la page

Viessmann Vitoplanar Notice D'utilisation page 34

Thermostat intégré dans un commutateur avec pave tactile

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
GB
Advanced settings
All manuals and user guides at all-guides.com
Call up the menu points "Settings" -> "Advanced settings".
!
Caution
Incorrect settings can damage your floor or your heating system.
We recommend that advanced settings are used only by qualified
contractors. Consult your dealer, or use the advances settings
with extreme caution.
"Heating system"
"NTC sensor"
"Hysteresis"
"Calibration"
"Pilot wire"
"Adaptivity"
"Information"
"Factory reset"
Adaptivity
The thermostat automatically starts/stops in advance to reach the
required temperature at the required time.
The learning period may take up to 2 weeks.
If Adaptivity is deactivated, the thermostat only starts/stops at the set
time.
34
Changes from heating to cooling
Changes the type of NTC sensor
(see installation instructions)
Matching of the switching hysteresis
Adjustment of displayed actual temperature
Changes the setback contact settings
See the description below
General software information
Resets all settings