DKS1000T - CONFIGURATION
Menu 1 - Changing the access password- type # 01
Type the new password (maximum 6 digits) and confirm with ' ' (e.g. 112233 ).
The keypad will sound a 3-second long beep. The password has been changed
N.B.: The password allows access to the keyboard management functions.
If you lose the password you will have to send the keyboard back to the manufacturer
to be reset.
type
Menu 2 - Backlighting setting parameters - type # 02
0
Backlighting level - Maximum
1
Backlighting level - Medium
2
Backlighting level - Minimum
type
Menu 3 - Backlighting activation mode - type # 03
0
Backlighting mode - Always OFF
1
Backlighting mode - Active on user event
2
Backlighting mode - Always ON
type
Menu 4 - Buzzer intensity setting - type # 04
0
Buzzer intensity - High sound setting
1
Buzzer intensity - Low sound setting
type
Menu 5 - Buzzer activation mode - type # 05
0
Buzzer activation mode - OFF
1
Buzzer activation mode - ON (sounds each time a key is pressed)
2
Buzzer activation mode - ON (sounds only for confirmation/error)
type
Menu 6 - Serial output mode - type # 06
0
Idle serial output level - Low
1
Idle serial output level - High
type
Menu 7 - Serial output configuration - type # 07
0
Serial protocol 8-N-1 - Speed 9600 bps
1
Serial protocol 8-N-1 - Speed 19200 bps
2
Serial protocol 8-N-1 - Speed 38400 bps
default
3
Serial protocol 8-N-1 - Speed 57600 bps
4
Serial protocol 8-N-1 - Speed 115200 bps
type
Menu 8 - Serial output voltage - type # 08
0
Voltage level - 5V
default
1
Voltage level - 3V
2
Voltage level - OPEN DRAIN
type
Menu 9 - Serial output format - type # 09
0
CARHF data format
default
1
GENERIC data format
Menu 10 - Return to factory settings - type # 10
default
Using this function you can reset the device to its default factory settings
meaning all the parameters modified in the SERVICE menu will be reset. To
start the procedure you must reinsert the access password and confirm by
pressing . e.g. after typing # 10 , type "password ".
20
default
default
default
default