CLEANING THE SPARK PLUG
This feature is obtained through a ceramic ignition
candle with a metal electrode. Keep these
components well clean to prevent difficult lighting
and check that the burner crown holes are not
obstructed.
TROUBLESHOOTING
WARNING! Refer to Safety chapters.
WHAT TO DO IF...
Problem
There is no spark when you try
to activate the spark generator.
The flame extinguishes immedi-
ately after ignition.
The flame ring is uneven.
IF YOU CANNOT FIND A SOLUTION...
If you cannot find a solution to the problem yourself,
contact your dealer or an Authorised Service
Centre. Give the data from the rating plate. Make
sure, you operated the hob correctly. If not the
servicing by a service technician or dealer will not
24
PERIODIC MAINTENANCE
Speak to your local Authorised Service Centre
periodically to check the conditions of the gas
supply pipe and the pressure adjuster, if fitted.
Possible cause
The hob is not connected to an
electrical supply or it is con-
nected incorrectly.
The fuse is blown.
Burner cap and crown are
placed incorrectly.
Thermocouple is not heated up
sufficiently.
Burner crown is blocked with
food residues.
be free of charge, also during the warranty period.
The instructions about the Service Centre and
conditions of guarantee are in the guarantee
booklet.
Remedy
Check if the hob is correctly
connected to the electrical
supply.
Make sure that the fuse is the
cause of the malfunction. If the
fuse is blown again and again,
contact a qualified electrician.
Place the burner cap and
crown correctly.
After lightning the flame, keep
the knob pushed for equal or
less than 10 seconds.
Make sure that the injector is
not blocked and the burner
crown is clean.