9.1 Installation of the Sheet Metal Flue
2
Fig. 14
23.02.2023
1 - Inner Flue
2 - 3.5 x 9.5 Flue Connection Plate Fixing Screws
3 - Flue Connection Plate
4 - 3.5 x 9.5 Flue Bottom Fixing Screws
1
The outer and inner sheet metal flues are assembled one within
the other (Fig. 14).
The cooker hood is set in the midst, and then the flue con-
necting plate is directly affixed to the wall, under the cover or
points E and F are marked after performing a measurement
(Fig. 12)
Drill points E and F with Ø6mm drill bit, and insert Ø6mm and
plastic dowels. Insert the flue connection plate with 3,9x22
screws (Fig. 12).
4
Affix the inner flue to the flue connection plate from its left and
right sides with two 3.5x9.5 screws, by pulling it upwards.
(Fig. 14)
Affix the outer flue with two 3.5x9.5 screws to the left and right
connection plates at the back of the cooker hood's body, from
the bottom (Fig. 14).
HOOD USER GUIDE ENGLISH
ASSEMBLY OF PRODUCT
Installation of the Sheet Metal Flue
21