Télécharger Imprimer la page

Oregon Scientific WMR100 Mode D'emploi page 11

Masquer les pouces Voir aussi pour WMR100:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
WIND DIRECTION / SPEED
The base station provides
wind
speed
and
wind
direction information.
To read the wind direction
fi nd the compass point the
is pointing to.
The timestamp records the date and time when storing
the wind speed readings.
To select the wind speed unit:
Press UNIT (at the bottom of the base station) to switch
between:
• Metres per second (m / s)
• Kilometers per hour (kph)
• Miles per hour (mph)
• Knots (knots)
The wind level is shown by a series of icons:
ICON
LEVEL
DESCRIPTION
N/A
N/A
N/A
<2 mph (<4km/h)
<2 mph (<4km/h)
Light
2-8 mph (3~13 km/h)
Moderate
9-25 mph (~14-41 km/h)
Strong
26-54 mph (~42-87 km/h)
Storm
>55 mph (>88 km/h)
To display the AVERAGE and GUST wind:
1. Press SELECT to navigate to the Wind Speed and
Wind Direction Area.
2. Press MODE to toggle between AVERAGE and
GUST wind readings.
To display the maximum speed and direction for
gust wind:
In the Wind Speed and Wind Direction Area, press
In the Wind Speed and Wind Direction Area, press
MEMORY /
ON/OFF to toggle between wind speed
/ MAX GUST wind readings. The timestamp is displayed
accordingly in the Clock Area.
To clear the memories and timestamp for the wind
readings:
In the Wind Speed and Wind Direction Area, press and
hold MEMORY /
ON/OFF to clear the readings.
To change the high gust wind speed alarm:
1. In the Wind Speed and Wind Direction Area, press
and hold ALARM to enter the high gust wind alarm
setting.
2. Rotate the dial left or right to set the desired values.
3. Press ALARM to confi rm the settings.
All manuals and user guides at all-guides.com
will show next to the Area.
To activate / deactivate the high gust wind speed
alarm:
1. In the Wind Speed and Wind Direction Area, press
ALARM repeatedly to select the desired alarm.
2. Press MEMORY /
deactivate the alarm.
UVI / BAROMETER / RAINFALL
The weather station works with one UV sensor and
one rain gauge. The station is capable of storing and
displaying the hourly history data for the last 10 hours
of UV index, and 24 hours of rainfall and barometric
pressure readings.
UVI
BAROMETER
The bar chart display shows the current and historical
data for the UV index, barometric pressure and rainfall
readings.
To view the UV / Barometer / Rainfall readings:
1. Press SELECT to navigate to the UV / Barometer /
Rainfall Area.
will show next to the Area.
2. Press MODE to toggle between UVI / Barometer
/ Rainfall readings. The corresponding icon will
appear:
UVI
BAROMETER
3. Rotate the dial left or right to view the historical data
for the selected area. The corresponding historical
readings are showing.
NOTE The number shown in the HR icon indicates how
long ago each measurement was taken (e.g. 2 hours
ago, 3 hours ago, etc.).
To select the measurement unit for the barometer or
rainfall readings:
In the UV / Barometer / Rainfall Area, press UNIT (at the
bottom of the base station) to switch between:
• For barometer: Millimeters of mercury (mmHg),
inches of mercury (inHg), millibars per hectopascal
(mb / hpa).
• For rainfall: Millimeters (mm), inches (in), inches per
hour
hour (in / hr)
hour (in / hr)
or millimeters per hour (mm / hr).
10
ON/OFF to activate or
RAINFALL
RAINFALL

Publicité

loading

Ce manuel est également adapté pour:

Wmr100a