Installation - for contractors
12.
See chapter „Commissioning".
13.
» Explain the appliance function to users and familiar-
ise them with its operation.
» Make users aware of potential dangers, especially
the risk of scalding.
» Hand over these instructions.
14.
The appliance fails to
There is no power.
deliver hot water.
The high limit safety
cut-out has respond-
ed.
Water can only be
The jet controller in
drawn at a reduced
the tap is scaled up.
rate.
Loud boiling noises in-
The appliance is
side the appliance.
scaled up.
14
All manuals and user guides at all-guides.com
15.
15.1
15.2
Remedy
Check the fuse/MCB
in your fuse box/distri-
bution panel.
Remedy the cause of
the fault. Reset the
high limit safety cut-
out by pressing its
reset button.
Descale or replace the
jet controller.
Descale the appli-
ance.
15.3
15.4
15.5
» Dismount the appliance for maintenance work.
Drain the appliance via the connector.
»
» Pull off the controller button.
» Remove the screw underneath the controller button.
» Remove the appliance cap.
» Remove the earth strap from the cylinder.
» Release the tie.
» Remove the upper insulation semi-shell.
» To include the steel cylinder in the equipotential
anode".
-