viking range corporation
pLanning
Interior Blower Installation
This downdraft blower system is
designed to be used to exhaust
airborne contaminants when
cooking with a variety of gas
or electric cooktops. It can be
mounted in island, peninsula, or
conventional wall locations.
This unit can be easily installed
following these basic steps:
Cut out the countertop opening.
Mount the unit in the cabinet.
Install the Model VIDV500
Interior Blower
Connect the ductwork and
electrical.
Install the cooktop.
note: the high level of air flow
of this appliance may effect the
gas flame on some types of gas
cooktops. This is NORMAL and
will cause no harm, but can be
corrected by lowering the speed
of the blower.
take MeaSUreMentS
. Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. The
Models VIPR101SS and VIPR101RSS will fit in most 30" wide
cabinets t he M odels V IPR161SS a nd V IPR161RSS w ill fi t i n m ost
36" w ide c abinets a nd t he M odels V IPR8SS a nd V IPR8RSS
will fit most 48" wide cabinets. However, it is recommended that
oversized cabinets be used for easier installation.
2. Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay s pecial a ttention t o t he a reas o f p otential i nterference h ighlighted
above. A countertop with (A) a raised lip and/or (B) a backsplash
may not allow enough flat countertop for a proper installation. Note
that 2" of flat countertop is required behind cooktop and that 1-3/4"
is necessary between the back edge of the cooktop and the inside
of cabinet back.
All manuals and user guides at all-guides.com
tYpicaL inStaLLation
CHIMNEY TOP
COUNTER
TOP
COOK TOP
AIR
VENT
GEAR
MOTOR
COVER
BLOWER
BOX
20 VAC
GROUNDED
OUTLET
3-1/4" X 10"
DUCT CONNECTOR
eLectricaL
SpeciFicationS
120 vac • 60 Hz • 4.0 a
All Units
Exterior Blower Installation
This d owndraft b lower s ystem i s
designed to be used to exhaust
airborne contaminants when
cooking with a variety of gas
or electric cooktops. It can be
mounted i n i sland, p eninsula, o r
conventional wall locations.
This unit can be easily installed
following these basic steps:
Cut out the countertop open-
ing.
Mount the unit in the cabinet.
•Install 0" round discharge
plate
Install Model VEDV900 or
VEDV200 (48" Model
ONLY) External Blower
Connect the ductwork and
electrical.
Install the cooktop.
note: the high level of air flow of this appliance may effect the gas
flame o n s ome t ypes o f g as c ooktops. T his i s N ORMAL a nd w ill c ause
no harm, but can be corrected by lowering the speed of the blower.
2
downdraft Ventilators
tYpicaL inStaLLation
COUNTER TOP
CHIMNEY TOP
COOK TOP
GEARMOTOR
COVER
0" ROUND
DISCHARGE
PLATE
0" ROUND DUCTWORK
eLectricaL
SpeciFicationS
120 vac • 60 Hz • 6.0 a (max.)
AIR
VENT
20 VAC
GROUNDED
OUTLET