12. Resin in drain line.
13. Too much water in brine tank.
14. Unit fails to draw brine.
15. Valve continuously cycles.
16. Flow to drain continuously.
SHOULD YOU NOTICE ANY NEW PROBLEMS WITH YOUR WATER, WATER2BUY HAS THE
CAPABILITIES TO SOLVE THEM.
AquaSmart products and systems reduce both natural and man-made water pollutants; and
provide the best water for each specific use and application. Your new Water2buy water softener
can be adjusted to handle to wide range of water problems, but it does have limitations. It has
been specified onto the basis of your water conditions at the time of sale. It is possible for the
chemical makeup of your water to change in time, and such changes cannot be predicted. Your
needs and uses may also change. Water2buy is ready to help you if any problem should arise.
With Water2buy, you get more than a quality product. Our reputation is based on prompt,
courteous, efficient attention to your needs. Selling water softeners is our full-time business, and
satisfied customers are our best assets. YOU GET THE SECURITY OF DEALING WITH AN
ORGANISATION THAT'S TRUSTED ALL OVER EUROPE.
AquaSmart is one of the leading brands of water softeners in the world. This leadership position is
not awarded it is earned. It means that a Water2buy product will never be an "orphan" because we
will always stand behind our warranties. It means that we will always strive to deserve your
confidence.
Copyright notice
Water2buy ™ and AquaSmart ™ are registered trademarks, all images, logos text and diagrams
belong to The water store limited. Copying of Water2buy ™ materials is strictly forbidden without
prior written consent.
3. Inlet of control plugged due to
foreign material.
1. Air in water system.
2. Incorrect drain line flow control
(DLFC) button.
1. Plugged injector or screen.
2. Foreign material in brine tank.
1. Drain line flow control is plugged.
2. Injector or screen is plugged.
3. Inlet pressure too low.
4. Internal valve leak.
1. Broken gear.
1. Valve settings incorrect.
2. Foreign material in control valve.
3. Internal leak.
Thank you for choosing Water2buy.com
Value, Quality, Service
Water2buy.com Aquasmart™ v3
Remove piston and clean control valve.
Check well system for proper air
eliminator control.
Check for proper flow rate.
Clean parts.
Clean parts.
Clean parts.
Clean parts.
Increase pressure to 25 PSI.
Replace seals, spacers, and piston
assembly
Replace faulty parts.
Check valve settings.
Clean control.
Replace seals, spacers, and piston
assembly.