THE BRINE
TIGHTEN THE BRINE SUCTION HOSE CONNECTION.
TANK IS
Diagram 7. Tighten the plastic nut (B) and brass nut (A) make sure the seal on both is airtight.
OVERFLOWING
WAHT SHOULD
I DO?
TIGHTEN THE CONNECTION BETWEEN THE CONTROL VALVE AND VESSEL
Diagram 7 (C) This is the threaded joint where the control valve joins onto the brine tank. Hold
the vessel steady inside the tank and twist the control valve tight.
CLEAN THE INJECTORS.
Diagram 8.
Unplug the control valve.
Turn the bypass valves fully anticlockwise Diagram 1 (I) into bypass position (perpendicular).
Using a screwdriver, remove injector screen and injector cap Diagram 8 (A)
Use a screwdriver to unscrew the outer injector (B).
Insert the screwdriver and unscrew the inner injector (C).
Tilt the unit to remove the inner injector. Caution the unit may be heavy, seek assistance.
Remove the screen gauze.
Clean screen gauze using a fine brush.
Flush the gauze with water until clean.
Flush water into the injector recess of the valve to flush out debris.
Clean the injector with a pin or paperclip.
Lubricate the O-rings on the injector. Lubricate the injector cap and lubricate the injector
screen with silicone lubricant.
Reinstall the injector, injector cap and injector screen. Do not over-tighten the plastic cap. Seat
the cap lightly into position. Over tightening may cause breakage of the plastic cap that may
not be immediately evident.
Plug in the control valve power.
Follow the setup and configuration process for your unit.
Slowly turn the bypass valves clockwise to open.
Diagram 8
Diagram 7
Water2buy.com Aquasmart™ v3