4. Installation
Caution
The installation site of the pump must be dry and well ventilated.
When installed in a closed room, a drainage connected to the sewers
must be installed.
The size of the floor drain depends mainly on the size of the swimming
pool and the circulation flow rate but also on possible leaks within the
pool water circulation system.
The ambient temperature must not exceed 40 °C.
Caution
Installation in the service area
The pump must be installed in the service area, e.g. operating room,
shaft or shed.
Caution
Implement appropriate measures to attenuate the noise generated by
the pump to avoid damage to the environment. Fastening the pump
to the foundation should be effected exclusively by means of bolts,
threads or dowels, in order to avoid preventing the removal of the motor
unit! Make sure that there is enough space between the fan cover
and the wall, minimum 50 mm. You also need enough space to permit
disassembly of the strainer basket, minimum 210 mm above.
The pump should be installed at water level
or below water level and in a horizontal
position, in order to keep the suction path as
short as possible and to reduce head loss.
The AQUA Plus Timer OKU is self-priming
and should never be installed more than
2 m above water level. Make sure that the
suction line is not leaky, otherwise the pumps
will prime insufficiently or not at all. We
recommend the installation of check valves
and shut-off valves, according to the type of
pump or plant. The adhesive bonds at the
suction and pressure lines require more time
to cure, allow at least 12 hours before starting
the pump.
| 12
W91.40.615-P
W91.40.617-P
W91.40.018-P