USER MODE
While the appliance is in programme selection mode:
1. Press and hold programme button until the indicator
In user mode can be changed:
The level of the water softener according to the water hardness.
The activation or the deactivation of the acoustic signal for end of programme.
These settings will be saved until you change them again.
ADJUSTING THE WATER SOFTENER
1. While the appliance is in user mode, wait until the indicator
flash. The current setting is indicated by the number of flashes of the indicator
pause + 5 flashes = level 5).
2. Press the programme button to change the setting. Each time you press the button, the level
increases. After level 10 you will start again from level 1.
3. Press the on/off button to confirm the setting.
THE WATER HARDNESS TABLE
German degrees
French degrees
(°dH)
47 -50
43 - 46
37 - 42
29 - 36
23 - 28
19 - 22
15 - 18
All manuals and user guides at all-guides.com
5x
(°fH)
84 - 90
76 - 83
65 - 75
51 - 64
40 - 50
33 - 39
26 - 32
starts to flash and the indicator
go off and the indicator
mmol/l
Clarke degrees
8.4 - 9.0
7.6 - 8.3
6.5 - 7.5
5.1 - 6.4
4.0 - 5.0
3.3 - 3.9
2.6 - 3.2
(e.g. 5 flashes +
Water softener
level
58 - 63
53 - 57
46 - 52
36 - 45
28 - 35
23 - 27
18 - 22
is on.
6x
starts to
10
9
8
7
6
1)
5
4
21

Publicité