F E AT U R E S - O P E R AT I O N S
C L E A N I N G / M A I N T E N A N C E
Automatic defrosting
If the room temperature drops down to 16 °C or lower,
the unit's temperature sensor will set the compressor
to dehumidify for 25 minutes and then shut off
automatically. The fan will keep running for 7 minutes to
defrost in a cycle.
NOTE: When the defrost icon is shown on the LCD display,
the compressor will shut off and the fan will run at high
speed.
Water Full Protection & Auto-Shutoff
When the water reservoir is full, the unit will sound an
alarm beeping 10 times (for about 5 seconds). The water
reservoir full icon will be displayed on the screen and the
unit will shut off automatically. This indicates that it is
time to empty the water reservoir before using the unit
again. Once the empty water reservoir is placed back into
the unit, it will take up to 3 minutes for the dehumidifier
compressor to work again. This is a protection feature.
If you wish to restart the unit without waiting, unplug it
from the electrical outlet and plug it in again.
Water drip Protection
When the water reservoir is removed for emptying, this
device will keep the condensed water that continues to
drip. Once the water reservoir is placed back in the unit,
it will release this water into the reservoir.
Continuous drainage
For added user convenience, this dehumidifier includes a
hose that can be attached to it to operate with continuous
drainage. To use it, simply remove the drain plug located
in the back of the unit and connect the PVC hose that
comes with the unit. Find a suitable location for the unit
where the open end of the hose can drain the outgoing
water into an appropriate receptacle or outside of your
home, far enough away from the foundation to ensure
proper drainage. The unit will now direct water from the
bypass port and through the hose, rather than into the
water reservoir.
All manuals and user guides at all-guides.com
NOTE: Please make sure to place the open end of the
hose flat on the ground ensuring it is not entangled.
CAUTION: The drain hose must be below the drain plug
in order for the unit to drain properly.
NOTE: To help prevent leakage, you should use a marker
to denote the location where the hose meets the housing
on the rear of the unit. Periodically check to make sure
this indicator has not moved away from the housing to en-
sure that your hose will not leak. Leakage inside the unit
will fall into the water reservoir. If this happens you can
empty the water reservoir by following the instructions
above in the "Emptying the Water Reservoir" section.
CLEANING ANd MAINTAINANCE
1. Turn the unit off and unplug it from the electrical
2. Carefully remove water reservoir to empty it. Rinse
3. Use a soft clean cloth to wipe the unit. Do not use
4. To clean the mesh filter, carefully remove the filter
NOTE: Do not expose unit to direct sunlight.
outlet.
the reservoir with warm water.
gasoline, paint thinner or other cleaning products to
clean the unit.
and clean it with a vacuum cleaner or rinse with cool
water. Place it in a well-ventilated location and allow
to dry before replacing filter into unit.