3. INSTALLATION AND CONNECTION (continued)
=
=
R
S
Power supply
400V 3N
Never use an electrical plug for the power supply.
The electrical power supply must have, in a suitable manner, an
omnipolar protection device of the D-curve circuit breaker type as well
as a 30mA protection differential circuit breaker (see following table).
Models
Power supply
D-Curve
circuit breaker
Cable section
Models
Power supply
D-Curve
circuit breaker
Cable section
Use an RO 2V/R 2V or equivalent power cord.
The cables sections are given for a maximum length of 25 m. They
must however be checked and adjusted according to the installation
conditions.
Always shut down the main power supply before opening the electrical
control box.
After a cut-off of the power supply, wait 10 minutes before accessing
the active internal parts of the equipment (power stored in the
capacitors).
= =
T N
∿
/ 50Hz
HP5171DT3
V/Ph/Hz 230V∿ 50Hz
A
mm
3G2.5
2
HP5211ET3
V/Ph/Hz
400V 3N∿ 50Hz
A
mm
2
K2
=
1
Dry contact 7 A max
potential free.
Priority heating function
HP5211DT3
230V∿ 50Hz
16
20
3G4
HP5251ET3
400V 3N∿ 50Hz
10
5G2.5
=
= =
2
3 4
Remote A1 On/Off contact
HP5251DT3
230V∿ 50Hz
25
3G4
HP5301ET3
400V 3N∿ 50Hz
12
5G2.5
HP5301DT3
230V∿ 50Hz
25
3G4
16
5G2.5
13