3. INSTALLATION AND CONNECTION (continued)
3.2 Pompe à chaleur
Place the heat pump outdoors and away from any enclosed technical
space.
Choose a location that is preferably sunlit and sheltered from dominant
winds.
The device must be perfectly accessible for later installation and
maintenance work.
Placed under a shelter, the minimum required distances mentioned
below must be respected in order to avoid any risk of air recirculation
and a deficiency in the unit's overall performance.
Preferably, install the heat pump on a flat and dissociated cement block.
The maximum installation distance between the unit and the swimming
pool is 15 metres.
The total length of the piping to and from the unit is 30 metres.
Insulate both the above ground and buried hydraulic piping.
The heat pump must be installed at a minimum distance from the pool
in compliance with NF C 15-100 (3.5 m from the water for France) or in
compliance with installation standards applicable in other countries.
Do not install the heat pump close to a heat source.
For installation in snowy regions we recommend sheltering the machine
to avoid snow accumulating on the evaporator.
Unit: mm
700 mm
Air inlet
10
Air outlet
700 mm
Air inlet
Air outlet
700 mm
Air inlet