PROBLEM
CAUSE
Empty hopper
Auger blocked
by a foreign
object (for
example nails)
The fire extinguish
Bad quality
and the stove
pellets
stops
Pellet drop value
too low "phase
1"
Check if on the
display there
is an "ACTIVE
ALARM"
Stove running
Automatica
and display
burning pot
showing "BURN
cleaning
POT CLEANING"
Not sufficient
combustion air
Obstructed
Flames are weak
exhaust
and orange
coloured, pellets
do not burn
properly and the
Obstructed stove
glass blackens
The fume fan is
out of order
Faulty fume
temperature
The exchanger
probe
fan continues to
turn even though
the stove has just
Faulty mother
cooled
board
Faulty or out
of order door
gaskets
Ash remains
along the stove
Not sealed fume
pipes
NICE - MIRIAM - CRISTAL - LEONORA - PRETTY - DIANA - KRISS - MARY
All manuals and user guides at all-guides.com
SOLUTION
Full the hopper.
Clean the auger.
Try other types of pellets.
Adjust the pellet loading.
Have the stove checked.
The stove is at minimum, fume fan at maximum. NO
PROBLEM!
Check as following: probable obstructions of the
combustible air inlet from the back or from the bottom
of the stove; burning pot obstructed holes with too ash
remains. Have the fan blades and auger cleaned.
The exhaust chimney is partially or totally obsturcted.
Contact an expert stove-repairer who checks the
stove from the exhaust up to the chimney pot. Provide
immediately for stove cleaning.
Provide immediately at the inner cleaning of the stove.
The pellets can burn also thanks to chimney flue
depression without the aid of the fume fan. Have the
fume fan immediately replaced. It can be noxious to
health to let the stove running without fume fan.
Replace the fume probe.
Replace the mother board.
Replace the gaskets.
Contact an expert stove-repairer who will immediately
provide for sealing the junctions with high-temperature
silicone and/or for replacing pipes with those in
compliance to current regulations. A not sealed fume
channelisation can be noxious to health.