9.3
GENERAL INSTALLATION
• Please check that the floor has an adequate load capacity. If the existing one does not satisfy this
requirement, appropriate measure should be provided (for example a plate for distributing the load).
• It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of
300 mm on the sides and 200 mm on the back, to enable an eficient appliance cooling and a good
distribution of heat in the room (see Fig. 13 page 61).
• For safety fire regulations the distances from flammable or sensible to heat objects (sofas, pieces of
furniture, wooden covering, etc...) must be respected, has described in Fig. 13 page 61.
• If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances must be further
increased with 1 meter.
• If the walls are made up of flammable materials, check the safety distances (see Fig. 13 page 61).
• At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary
please install a fire resistant plate on the concerned walls.
• In some countries also masonring load-bearing walls are considered flammable.
9.4
SIDE PANEL ASSEMBLY
Fig. 14 - Upper screws removal
• Remove the top cover: unscrew the 2 upper screws and the 3 backward screws (see Fig. 14 page 61
NICE - MIRIAM - CRISTAL - LEONORA - PRETTY - DIANA - KRISS - MARY
All manuals and user guides at all-guides.com
Fig. 13 - General installation
LEGEND
Fig. 13 page 61
1
Stove
2
Minimum lateral distance = 300 mm
3
Minimum rear distance = 200 mm
4
Minimum front distance = 1000 mm
Fig. 15 - Backward screws removal
EN
61