INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Tools needed
@
Level
@
Flat-blade screwdriver
@
Utility knife
@
Pliers
@
Scissors
@
Bucket
@
200 mm (8") or 250 mm
(10") adjustable wrench
Parts supplied
Remove parts bag from washer. Check that all parts were
included.
@
1 Hose clamp
@
2 Inlet hoses
@
4 Flat water hose washers
@ 2 Front-leveling legs
with nuts
@
1 Drain hose
@
Hose adapter
Clothes
Capacity:
Technical
Specifications:
220 — 240 V, 50 Hz. AC
MAT14PD: 5.9 Kg Max.
650 Watts
IMPORTANT:
Do not install or store the washer where it will
be exposed to the weather. Do not store or operate the washer
in temperatures at or below 0°C (82°F). Some water can remain
in the washer and can cause damage in low temperatures.
Proper installation is your responsibility.
You will need:
@ A water heater set to deliver 60°C (140°F) water to the washer.
@ An earthed electrical outlet located within 1.2 m (4 ft) of where
the power cord is attached to the back of the washer. See
"Electrical Requirements."
Recessed Area and Closet Installation Instructions
This washer may be installed in a recessed area or closet.
The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes
and ordinances.
If closet door is installed, the minimum unobstructed air
openings in the top and bottom are required. Louvered doors
with equivalent air openings are acceptable.
Closet door
2
a
pe
-a@— 356 mm
3.10
m ?
"
.
a ny
(14") max
OVO
eb
q
5
432 mm
A
e
(17°)
EB
1
oz
a
Y
Cj
pe)
<- 102 mm
1.55
m ?
"ymi
os
ey
(4") min.
oI
A
a
Oomm
Omm
(0") '| ae
=
(-
(0")
|
- 25 mm (1") min.
Recessed front view
Closet side view
Hot and cold water taps located within 1.2 m (4 ft) of the back
of the washer, and provide water pressure of 69-690 kPa
(10-100 psi). A pressure reduction valve should be used in the
supply line where inlet pressure entering the building exceeds
690 kPa (100 psi) to prevent damage to the washer mixing
valve.
@ A
level floor with a maximum slope of 25 mm
(1") under entire
washer.
@ A sturdy floor to support the washer weight (washer, water,
and load) of 143 kgs (815 Ibs).
@ A300 mm (12") minimum riser to provide an air cushion and
prevent noise and damage to valves for a single washer
installation.
@ A floor drain should be provided under the bulkhead.
Prefabricated bulkheads with electrical outlets, water
supply lines, and drain facilities should be used only
where local codes permit.
NOTE: Front access to the pump area is available by removing
No. T20 TORX® security screws and then removing the front
panel.
®f Torx is a registered tradernark of Saturn Fasteners, Inc.
4
3.10 m?
I
8")
Front
Closet
View
door
76mm
3"
1.55 m*
1
(24 in?)*
S
:
*Opening is the minirmum for a closet door.
Louvered doors with equivalent air openings are acceptable.
Additional spacing should be considered for the ease of
installation and servicing.
Additional clearances may be required for wall, door, and floor
mouldings.
Additional spacing of 25 mm (1") on all sides of the washer is
recommended to reduce noise transfer.
Companion spacing should also be considered.