Problem
There are white stains on the dishes.
The dishes are not dry.
There are rust stains on the dishes.
FAULT CODES
If the appliance has a fault the start/pause button or one or more of the program-step indicators blink.
Start/pause
Fault
button
Overflow/Leakage
-
Drain time out
Blink
Possible cause
One of the spray arms is clogged.
The filters are clogged.
The filters are not placed correctly.
The water drain pump is clogged.
The amount of detergent is
insufficient.
The level of rinse aid consumption is
set too low.
There is a high level of water
hardness and no salt is used.
The cap of the salt reservoir is not
closed correctly.
The selected program does not
include drying.
The level of rinse aid consumption is
set too low.
The stainless steel quality of the
dishes is insufficient.
There is a high level of salt in the
water.
The cap of the salt reservoir is not
closed correctly.
Any spilled salt during filling of
the salt reservoir was not cleaned
immediately.
There is a problem with the
grounding of the mains supply.
Wash
Dry
End
Blink
-
Blink
-
-
Blink
Possible solution
Clean the spray arms. Refer to
Cleaning the spray arms
section
Clean the filters. Refer to section
Cleaning the filters
.
Make sure that you correctly place
the filters.
Make sure that the water drain pump
is not clogged.
Make sure that you fill the detergent
reservoir with a sufficient amount of
detergent. Refer to section
detergent reservoir
.
Adjust the level of rinse aid
consumption. Refer to section
Setting the level of rinse aid
consumption
.
Fill the salt reservoir. Refer to
Filling the salt reservoir
section
Make sure that the cap of the salt
reservoir is closed firmly.
Choose a program that includes
drying. Refer to section
Adjust the level of rinse aid
consumption. Refer to section
Setting the level of rinse aid
consumption
.
Make sure that you only clean
dishwasher-safe dishes in the
appliance.
Adjust the level of salt consumption.
Setting the level of
Refer to section
salt consumption
.
Make sure that the cap of the salt
reservoir is closed firmly.
Make sure that you clean any spilled
salt immediately and run a full
program to prevent corrosion.
Contact an authorized electrician.
Notes
During normal operation only leakage is
shown.